WARNING: ALL WIRING AND INSTALLATION MUST BE SUPERVISED BY A SUITABLY
QUALIFIED PERSON.
WARNING: DO NOT INSTALL THIS SHOWER WHERE IT MAY BE SUBJECTED TO
FREEZING CONDITIONS
We recommend that the installation is done in the following sequence.
a. Fixing the shower to the wall
a. FIXING THE SHOWER TO THE WALL
1. Position the riser rail at a convenient height for majority of users as detailed in Diagram 1a/b
and mark its position.
2. Position the heater so that the top of the unit is horizontal and level with, or a maximum of
0.3 metres (1ft) below the top of the riser rail. Choose a flat piece of wall to avoid the
possibility of distorting the backplate thus making the front cover a poor fit.
3. Adjust the position to get the most convenient arrangement taking the following into account.
The heater must not be mounted in the direct spray from the handset.
The handset must not be able to come into contact with used water in the cubicle, bath or
basin. If it can, even after the hose has been retained by the soap dish (see Diagram 10), a
vacuum breaker must be fitted (available from us).
4. Fix the riser rail with screws provided. The fixing holes at the base of the brackets will be
revealed by removing the plastic fronts. Assemble as shown in Diagram 10).
5. Decide the position of the electrical cable into the unit.
If top or bottom entry is chosen, cut away the walls in the backplate as shown in Diagram 3.
6. Decide the position of entry of the cold water pipe into the unit.
If top or bottom entry is chosen, carefully cut away the relevant walls of the backplate as shown
in Diagram 2.
If bottom entry is chosen, refer to note 5 in the plumbing section.

HOW TO INSTALL YOUR CREDA SHOWER

b. Plumbing
c. Electrical connections
3
d. Commissioning