Procurar online ou descarregar pdf Manual de instalação e do utilizador para Produto de canalização Creda 570. Creda 570 12 páginas. Pumped electric shower
Thank you for purchasing a quality Creda Shower manufactured in England.
Section
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to install your Creda Shower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to maintain your Creda Shower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to use your Creda Shower (Detailed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What to do if things go wrong (1) Self Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Common Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What to do if things go wrong (2) Professional Service . . . . . . . . . . . . . . . . . . . . . . .
Creda After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How your Creda Shower Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Filters and Assembly of Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Guarantee and Contact Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To enjoy your new shower at its best, please take time to read this manual thoroughly to
familiarise yourself with all instructions, BEFORE beginning installation.
If you experience any difficulty with the installation or operation of your new
shower, then please refer to the "What to do if things go wrong" section in this
1. Your shower has been designed for convenience, economy and safety of use, provided that it is
installed, used and maintained in good working order and in accordance with our instructions and
recommendations.
2. All wiring and installation must be supervised by a suitably qualified person.
3. THIS APPLIANCE MUST BE EARTHED.
4. This Creda pumped electric shower is designed to heat and boost the flow of stored
domestic cold water, which is gravity fed from a static cold water cistern.
Under no circumstances should this unit be connected directly to the mains cold
water supply.
5. The cold water cistern should have a minimum capacity of 114 litres (25 gallons).
There must be a minimum head of water of 8cm (3") and a maximum head of 10m
(33ft) between the bottom of the cold water cistern and the top of the shower unit.
Under no circumstances should any of the pipework supplying the shower unit rise
above the level of the bottom of the cold water cistern.
6. The installation must be in accordance with the current edition of BS.7671 (the "IEE Wiring
Regulations") and "Part P" of the "Building Regulations" in force at the time of installation.
Installations outside England and Wales must also conform to any local regulations in effect.
This appliance is intended to be permanently connected to the fixed electrical wiring of the mains
supply with its own dedicated supply.
7. This appliance must NOT be fitted where it may be subjected to freezing conditions
8. DO NOT switch the appliance on if you suspect it of being frozen.
Wait until you are sure it has thawed out.
9. DO NOT fit any sort of tap or control on the appliance outlet. The appliance is designed to have
an open outlet and should only be used with "Creda" recommended fittings.
10. Take care to avoid restricting the outlet of the pressure relief device. If water is discharged from
the pressure relief device, maintenance will be required before the appliance can be safely used.
11. Isolate the mains electrical and water supply before removing the front cover of the appliance.