Figure 2
SUPPORT
PLATE
LEDGE
MOUNTING BRACKET
3. The natural gas source line must be installed underground between each vessel, as shown in Figure 2.
4. The natural gas source line must be reduced to 1/2" NPT for fire tables 42"+ and 3/8" NPT for fire vessels 24" - 36".
5. Using pipe sealer, attach supplied flex line to natural gas source line. Then attach the other end of the flex line to
key valve assembly. Do not kink or make a tight radius bend on the gas hose.
6. From Key Valve Assembly connect Flex Line to the Burner Assembly.
7. Check all gas connections tight, position the burner assembly so that it sits level in the bowl.
Rotate as required so that the gas hose rests in a compact position.
Key Valve Assembly
(Inside View)
NOTE: Leak Test – it is highly recommended to perform a gas leak test at this point in the install.
Turn on the gas supply and then, using a soapy water solution spray on the gas line connections
to ensure no leaks exist.
SUPPORT PLATE
FLEX LINES
DRAIN
BURNER RING
NATURAL GAS SOURCE LINE
Key Valve Assembly
(Outside View)
KEY VALVE
ASSEMBLY
5