Digilock NEXT Sola3 Keypad Manual do produto - Página 3

Procurar online ou descarregar pdf Manual do produto para Fechaduras Digilock NEXT Sola3 Keypad. Digilock NEXT Sola3 Keypad 5 páginas. Key managed
Também para Digilock NEXT Sola3 Keypad: Manual do produto (9 páginas)

Digilock NEXT Sola3 Keypad Manual do produto
Programming Instructions
Assign a New User Code (for assigned use functionality only)
a.
Press = ` [Manager Code] ` . A two-tone beep will be heard and the green LED will turn on.
b.
Press = [new assigned 4-digit User Code] ` . A two-tone beep will be heard.
c.
Press = [the same new assigned 4-digit User Code] ` . Two sets of two-tone beeps will be heard and the green LED will turn off.
Set Additional Lock Features (for shared use functionality only)

Auto Unlock

When in shared use functionality, each lock can be programmed to auto unlock after a set number of hours. The default setting is OFF
(does not auto unlock).
To Turn on Auto Unlock for Default 12 hours:
a.
Press = ` [Owner Code] ` . The LED will turn on.
b.
Press = 9 3 ` . A two-tone beep will be heard and the LED will turn off.
c.
The lock is set to auto unlock after 12 hours from last use.
To Turn on Auto Unlock for Custom Number of Hours:
a.
Press = ` [Owner Code] ` . The LED will turn on.
b.
Press = 9 5 ` . A two-tone beep will be heard and the LED will remain on.
c.
While the LED is on, enter the number of hours from 1 - 99 then press ` .
d.
Two sets of two-tone beeps will be heard and the LED will turn off.
For example: Press 8` to set the lock to auto unlock after 8 hours from last use.
To Turn off Auto Unlock:
a.
Press = ` [Owner Code] ` . The LED will turn on.
b.
Press = 9 4 ` . A two-tone beep will be heard and the LED will turn off.
Product Guide
Code Managed
Keypad
Shared & Assigned Use Functionality
3