RF Receiver Led's (indicators) :
Red Led :
'flashing' :
'steady on' :
'slowly plusing' : indicates a valid install code has been
Green Led :
'steady on' : - indicates demand for heat
'off' :
b) Checking the hard wired circuit :
1. Rely the RF-Max receiver to the mains. Check that no ther-
mostat in the heating network request warm. The red LED
should be off.
2. Press the Test button. The Green Led should come on.
Check that the boiler and/or motorised valve have been
operated. Remember to allow adequate time for the valve
to open. Press Test button again. The green led should
go out closing any valve and switching off the boiler.
Nota : the thermostat automatically leaves the test mode
after 15 minutes.
c) Checking the RF circuit
1. To install thermostat with the RF receiver press and hold
the OK and COPY keys together in Auto mode for 3
seconds. The DigiMax 210 will then transmit its unique
digital code every 10 seconds for the next 5 minutes. The
display will show flash ']]]' while this is happening.
indicates receiving an RF signal
indicates a fault condition e.g. RF signal
not being received
received
- no demand for heat i.e. heating call
satisfied