b) Installation
1. Set the security console mode switch to the THERM posi-
tion.
2. To install a thermostat with the console, press and hold
its + and - keys together for 3 seconds. The DigiMax 210
will then transmit its unique digital code every 10 seconds
for the next 5 minutes. The display will show flash ']]]'
while this is happening.
3. After a few seconds you should hear a "bip" from the con-
sole and the first zone indicator should come on or, if you
have already intalled thermostats with the console, the
next available free zone will be indicated.
4. Go to the thermostat and press any key to stop the trans-
mission. The display will stop flashing ']]]' and return to
normal.
5. Repeat this procedure for thermostat 2, 3 and 4. The first
thermostat will be installed on zone 1, the second will be
installed on zone 2...., the fourth on zone 4.
6. On the security console, reset the mode switch to Run1 or
Run2
Each thermostat will transmit a message every 5 minutes. If
during 20 minutes, the console does not receive any signal
from a thermostat, its RECORD LED will flash.
You can then put the slide switch to the THERM position to
see which zone (thermostat) has a problem.
The Maxi Controller transmits an X10 message on the unit
code of the zone allocated by the security console (see above)
and on the house code of the console + 1.
i.e. : If the console is on Housecode A,
- thermostat on zone 1 will generate message on code B1,