Digiplex DGP2-PS17 Manual rápido - Página 2
Procurar online ou descarregar pdf Manual rápido para Fonte de alimentação Digiplex DGP2-PS17. Digiplex DGP2-PS17 2 páginas.
PGM Test Mode
Entering section [020] will activate the PGM for 8 seconds to verify if the
PGM is functioning properly.
AC Failure Report Delay
The value programmed in section [002] represents how long the Power
Supply Module will wait before reporting an AC power failure to the control
panel. To program the timer, enter a 3-digit decimal value (000 to 255
minutes) into section [002]. Default: Instant reporting (000).
S
Section [020]
PECIFICATIONS
AC Power:
Aux. Power:
Battery:
Number of Outputs:
Section [002]
Control Panel
Compatibility:
Figure 1: Connecting the DGP2-PS17
16Vac, 20/40VA, 50 - 60Hz
12Vdc, typical 600mA, 700mA max.
12Vdc, 4Ah minimum
1 form "C" relay rated @ 125V, 5A receptive load
Any Digiplex (DGP-48) or DigiplexNE (DGP-NE96)