FIBARO FGMS-001 Manual de instruções - Página 5

Procurar online ou descarregar pdf Manual de instruções para Acessórios FIBARO FGMS-001. FIBARO FGMS-001 11 páginas. Motion sensor
Também para FIBARO FGMS-001: Manual de instruções (20 páginas), Manual de instruções (2 páginas)

FIBARO FGMS-001 Manual de instruções
8

#5: Operating the device

Controlling the Motion Sensor using the B-button:
The Motion Sensor is equipped with a B-button, which allows to use
the menu and additionally perform the following actions:
1x click: wake up the device or select the desired menu option (if
menu is active)
3x click: add/remove the device to/from a Z-Wave network
Holding: enter/navigate through the menu
Visual indications:
The Motion Sensor is equipped with a LED diode, signalling sensor's
operating modes and alarms. In addition the visual indicator may in-
form of the Z-Wave network range and the current temperature.
visual indicator signalling modes:
1. Motion Alarm colour will vary depending on the temperature. The
colour and the signalling mode can be set in parameter 80.
2. Tamper alarm is signalled with an alternating blinking in LAPD
colours (red - blue - white).
3. The Z-Wave node Info command frame is signalled with glowing
in blue. node Info command frame is sent each time the device
wakes up.
4. Menu position is signalled with assigned illumination colour.
Menu:
Menu allows to perform Z-Wave network actions. In order to use the
menu:
1. Press and hold the B-button.
2. Wait for the device to indicate desired position with a colour:
VIOLET - Z-Wave network's range test
YELLOW - device reset
3. Release the B-button.
4. Click the B-button to confirm selection.
Waking up the Motion Sensor:
The Motion Sensor needs to be woken up to receive information on
new configurations from the controller, like parameters and associa-
tions.
To wake up the sensor manually triple click the B-button located in-
side the housing.
OPERATInG ThE DEvICE
Controlling the Motion Sensor with FIBARO Home Center controller:
The Motion Sensor has a bulit-in motion detector, temperature sensor
and light intensity sensor, which make it a multi-channel device. In the
home Center interface it will be presented as three devices.
Seismograph mode:
The Motion Sensor can be configured to work as a simple earthquake
detector, by setting the parameter 24 value to 4. Reports with scale of
the vibrations (in the Modified Mercalli Scale) will be sent at the time
intervals specified in parameter 20. First report will be sent immedi-
ately after vibrations have been detected. Once the vibrations cease,
reports will stop being sent.
Orientation in space:
The Motion Sensor has a built-in accelerometer. When the value of
parameter 24 is set to 2 or 3, Z-Wave network controller will be in-
formed on the Sensor's orientation in space by sending report after
triggering tamper alarm.
Resetting the Motion Sensor:
Reset procedure erases the memory, including all information on the
Z-Wave network and the main controller.
1. Open the cover.
2. Press and hold the B-button.
3. Wait for visual indicator to glow yellow (2nd menu position).
4. Release the B-button.
5. Click the B-button to confirm selection.
6. After few seconds the device will be reset, which is signalled with
the red, fading visual indicator colour.
9
i
NOTE
Resetting the device is
not the recommend-
ed way of removing
the device from the
Z-Wave network. use
reset procedure only
if the primary con-
troller is missing or
inoperable.
Certain
device removal can be
achieved by the pro-
cedure of removing
described in "Adding/
removing the device"
on page 6.
OPERATInG ThE DEvICE