Removing metal mesh grease filter
Open the lock and fold down the metal grease filter. While
1.
doing this, place the other hand under the metal grease filter.
Take the metal grease filter out of the holder.
2.
For edge extraction filters, pull the metal grease filter
downwards. While doing this, place the other hand under the
metal grease filter.

Trouble shooting

Malfunctions often have simple explanations. Please read the
following notes before calling the after-sales service.
:
Risk of electric shock!
Incorrect repairs are dangerous. Repairs may only be carried
out and damaged power cables replaced by one of our trained
after-sales technicians. If the appliance is defective, unplug the
appliance from the mains or switch off the circuit breaker in the
fuse box. Contact the after-sales service.
Malfunction table
Problem
Possible cause Solution
The appliance
The plug is not
does not work
plugged in.
Power cut
Faulty fuse
The lighting
The bulbs are
does not work.
faulty.
--------
Connect the appliance to
the electricity supply
Check whether other
kitchen appliances are
working
Check in the fuse box to
make sure that the fuse for
the appliance is OK
For information on chang-
ing the bulbs, see the
"Replacing Bulbs" section.
For additional filters, open the lock and fold down the metal
grease filter. While doing this, place the other hand under the
metal grease filter.
Notes
Grease can accumulate in the bottom of the metal grease
filter.
Hold the metal grease filter level, otherwise grease will drip
out.
Clean the metal grease filter.
3.
Installing the metal mesh grease filter
Insert the metal mesh grease filter.
1.
While doing this, place the other hand under the metal mesh
grease filter.
Fold the metal mesh grease filter upwards, locking it in place.
2.
Replacing bulbs
:
Risk of electric shock!
When changing the bulbs, the bulb socket contacts are live.
Before changing the bulb, unplug the appliance from the mains
or switch off the circuit breaker in the fuse box.
Important Only use a bulb of the same type and same power
(see the bulb holder or rating plate inside the appliance) – to
do this, remove the metal mesh grease filter.
Replacing halogen bulbs
Note: When inserting halogen bulbs, do not touch the glass
tube. Use a clean cloth to insert the halogen bulbs.
Carefully remove the bulb ring using a suitable tool.
1.
Pull out the bulb and replace it with a bulb of the same type.
2.
Insert the bulb cover.
3.
Insert the mains plug or switch on the fuse again.
4.
LED lights
Defective LED lights may be replaced by the manufacturer, their
customer service or a qualified technician (electrician) only.
:
Risk of injury!
The light emitted by LED lights is very dazzling, and can
damage the eyes (risk group 1). Do not look directly into the
switched on LED lights for longer than 100 seconds.
9