Actuonix LAC Manual de configuração do utilizador - Página 4
Procurar online ou descarregar pdf Manual de configuração do utilizador para Controlador Actuonix LAC. Actuonix LAC 9 páginas. Usb control and configuration of the linear actuator control board
Speed –
Fully counter clockwise, sets the speed to zero. Fully clockwise, sets the speed
to maximum.
Accuracy –
Fully clockwise rotation sets the precision to maximum. Rotating counter
clockwise increases the distance around the desired position where the actuator will stop
moving. If the actuator is jittery, reduce the precision slightly.
Advanced USB control options:
The included Advanced Configuration Program allows all the manual settings, and many
other control values, to be set by USB.
The Direct Control Tab, shown above, allows simple USB control of Position and the
four regular potentiometer controls. All these controls accept values from 0 to 100
percent.
The Advanced Configuration Tab provides full configuration control. Values can be set
to override the defaults, and the potentiometers, by pressing the Disable Defaults button.
The entered values will then be retained even when power is cycled. To return to the
default state, reconnect to the LAC Configuration Utility and press the Re-enable
Defaults button.