Argo AWICS19 Manual de instruções de instalação - Página 16
Procurar online ou descarregar pdf Manual de instruções de instalação para Ar condicionado Argo AWICS19. Argo AWICS19 18 páginas. Split air conditioner system
17 - PARAMETERS TABLE
EN
Par.
Parameter name
P00
Factory default reset
P01
Software version
P03
Carrier frequency
infrared signal
P05
Temperature scale
P06
Transmission channel
P08
Communication address/
refrigerant circuit
P09
Humidity threshold setting
P12
ECO mode power input limit
P13
Room Air Temperature hea-
ting shift
P30
Special command
WIRED CONTROLLER
P1
RESET DEFAULT VALUES
P6
TLC CHANNEL
P8
CIRCUIT ADDRES
P9
RH TRESHOLD
P12
ECO MODE %
P13
RAT CORRECTION
P14
ANTIFREEZE CORRECTION
P15
MODBUS ADDRESS
P16
MODBUS BAUD RATE
P17
PARITY MODE
P18
FAN SPEED SHIFT
LCD CONTRAST
LCD BRIGHTNESS
UNIT TYPE
UNIT SW CODE
UNIT SW VERSION
PANEL SW VERSION
Min
Default
Max
0
0
3
0
-
7
0
0
1
0
0
1
0
0
3
0
0
8
0
50
99
30
75
99
0
3
10
0
0
1
OFF
0
A
50%
75%
0
0
1
19200
1
0
50
90
16
Values
0 = No action
1 = Reset all remote control parameters to facto-
ry default value
2 = Reset all unit parameters to factory default
value
Software version of the remote controller
0 = 33 kHz
1 = 38 kHz
0 = °C (Celsius)
1 = °F (Fahrenheit)
0 = Channel #0
1 = Channel #1
2 = Channel #2
3 = Channel #3
See installation manual. Do not modify during
operation.
Threshold % relative humidity
When ECO mode is selected, max electrical
power input of the unit is limited to P12:
30 = 30% of Max Power Input
31 = 31% of Max Power Input
...
99 = 99% of Max Power Input
0 = 0°C
1 = 1°C
...
10 = 10°C
This parameter can be modifi ed according to the
stratifi cation of the air during heating operation
1=activation of auto-addressing procedure