Cisco ASR 5500 Manual de instalação - Página 2
Procurar online ou descarregar pdf Manual de instalação para Hardware de rede Cisco ASR 5500. Cisco ASR 5500 31 páginas.
Também para Cisco ASR 5500: Visão geral do procedimento de instalação (6 páginas)
Using the CLI to View Status LEDs
Using the CLI to View Status LEDs
Status LEDs for all cards can be viewed via the CLI by entering the Exec mode show leds all command.
[local]host_name#
The following displays a sample of this command's output.
Slot 01: Run/Fail: Green | Active: Off
Slot 02: Run/Fail: Green
Slot 03: Run/Fail: Green
Slot 05: Run/Fail: Green
Slot 06: Run/Fail: Green
Slot 08: Run/Fail: Green
Slot 11: Run/Fail: Green
Service: Off
Slot 12: Run/Fail: Green
Service: Off
Slot 13: Run/Fail: Green
Slot 14: Run/Fail: Green
Slot 15: Run/Fail: Green
Slot 16: Run/Fail: Green
Slot 17: Run/Fail: Green
The status of the two Power Filter Units (PFUs) can be viewed by entering the Exec mode show power chassis
command.
Checking the LEDs on the PFU
Each PFU has four LEDs along the top edge of its front panel. You must unsnap the top front cover from the
chassis to view these LEDs. Each LED is associated with one of the four -48 VDC power feeds connected to
the PFU.
Each LED on the PFU should illuminate blue for normal operating conditions.
Figure 1: PFU LEDs
The possible states for these LEDs are described in the following table. If the LED is not blue, use the
troubleshooting information below to diagnose the problem.
Troubleshooting
2
show leds all
| Active: Off
| Active: Off
| Active: Green
| Active: Off
| Active: Off
| Active: Green
| Active: Green
| Active: Green
| Active: Green
| Active: Green
| Active: Green
| Active: Green
| Redundant: Green
| Redundant: Green
| Redundant: Green
| Redundant: Green
| Redundant: Green
| Redundant: Green
| Redundant: Green
| Redundant: Green
| Redundant: Green
| Redundant: Green
| Redundant: Green
| Redundant: Green
| Redundant: Green
Troubleshooting
Master: Green
Master:Off
Status: Green
|
Status: Green
|