Installation, Maintenance, and Upgrade
• #1 Phillips screwdriver
• The following items from the FIPS kit:
• The following items from the Firepower 4100 series accessory kit:
Step 1
Copy the serial number on a label and attach it to the chassis where it can be retrieved easily for future use if needed.
To find the serial number, see
Step 2
Pull the chassis out of the rack until the release latches catch.
Step 3
If you have not already done so, attach a slide rail locking bracket to each side of the chassis using the six 8-32 x
0.375-inch Phillips screws provided in the accessory kit.
You should have completed this step while preforming the procedure described in
Note
Figure 15: Attach the Slide Rail Locking Bracket to the Side of the Chassis
1
Chassis
• One FIPS opacity shield
• Four 8-32 x 0.375-inch screws used to attach the FIPS opacity shield to the cable management
brackets
• 15 tamper-evident labels (TELs)
• Two cable management brackets
• Four 8-32 x 0.375-inch screws used to attach the cable management brackets to the slide rail locking
brackets
Serial Number
Location.
2
Slide rail locking bracket
Installation, Maintenance, and Upgrade
Install the FIPS Opacity Shield
Rack-Mount the
Chassis.
23