Cisco GS7000 Manual de instruções de instalação - Página 8

Procurar online ou descarregar pdf Manual de instruções de instalação para Hardware de rede Cisco GS7000. Cisco GS7000 13 páginas. Gainmaker node forward local injection module
Também para Cisco GS7000: Manual de manutenção (15 páginas), Resolução de problemas (4 páginas), Manual de resolução de problemas (12 páginas)

Cisco GS7000 Manual de instruções de instalação
FLI Module Installation

Closing the Housing

Close the housing as follows.
Ensure any worn gaskets are replaced, and the gaskets are clean and in the
1
correct position.
2
Carefully close the lid.
3
For strand-mounted housings, pull the lid away from the base and remove the
slack from the hinge before rotating the lid up toward the base.
4
Ensure no cables are pinched between lid and base.
Secure lid to base with bolts. Tighten from 5 to 12 ft-lbs (6.8 to 16.3 Nm) in the
5
sequence shown in the following illustration. Repeat the sequence twice, ending
with the final torque specification.

Receiver/Transmitter Module Removal and Replacement

Depending on the module population of your particular node, it may be necessary to
relocate or remove and replace an optical receiver or transmitter to facilitate the
installation of the FLI Module.
If necessary, complete the following steps to remove and replace an optical receiver
or optical transmitter.
1
Open the node housing.
Carefully tag and remove any optical fibers from the receiver or transmitter
2
module.
8
CAUTION:
Use caution when closing housing. Improper closing may result in the Model
GS7000 Node not being sealed from the environment.
4019330 Rev C