Dimplex 6910000100 Manual de serviço - Página 12
Procurar online ou descarregar pdf Manual de serviço para Lareira de interior Dimplex 6910000100. Dimplex 6910000100 18 páginas.
Também para Dimplex 6910000100: Manual de serviço (18 páginas)
Figure 3
Preparation for Service
NOTE: All components are replaceable from the front
!
of the fireplace while the unit is mounted in the wall.
Tools Required: Philips head screwdriver
WARNING: Disconnect power before attempting any
maintenance or cleaning to reduce the risk of electric
shock or damage to persons.
CAUTION: If unit was operating prior to servicing allow
at least 10 minutes for lights and heating elements to cool
off to avoid accidental burning of skin.
NOTE: All instructions are created for replacement
!
of the XLF50 components and as a result the number of
screws may differ for the XLF60, XLF74, and XLF100.
1. Turn the breaker off at the electrical panel.
2. Remove the front glass assembly by removing the 2
screws (1 on the left and 1 on the right side, located
just inside the top front vent opening). These screws
secure the front glass panel to the inside of the fire-
place. (Figure 4)
3. Lift the front glass assembly out of the unit and care-
fully place the glass assembly aside in a safe location.
4. Remove the decorative acrylic ember-bed pieces from
the media tray, which lies along the bottom of the inter-
ior partially reflective glass. A medium sized container
such as a bucket or a box will be needed to keep the
acrylic ember-bed pieces together.
5. Attach the suction cup to the partially reflective glass to
assist with removal (XLF74 & XLF100.)
6. Remove the 12 screws from the glass retaining brack-
et, starting on either end and working your way to the
12
XLF50
50.31 in [1278 mm]
XLF60
60.31 in [1532 mm]
XLF74
74.31 in [1887 mm]
XLF100 100.31 in [2548 mm]
XLF50 51.41 in [1306 mm]
XLF60 61.41 in [1560 mm]
XLF74 75.41 in [1941 mm]
XLF100 101.41 in [2576 mm]
Figure 4
Figure 5
4.34 in.
110 mm
5.79 in.
147 mm
www.dimplex.com