Parameter
Number
Hex / Decimal
2 (0x02)
Enable/Disable waking up for 10 minutes when re-power on (battery mode) the
MultiSensor.
1. Value = 0, disable.
2. Value =others, enable.
3 (0x03)
1. The default PIR time is 4 minutes. The Multisensor will send BASIC SET CC
(0x00) to the associated nodes if no motion is triggered again in 4 minutes.
2. Range: 10~3600.
Note:
(1), The time unit is second if the value range is in 10 to 255.
(2), If the value range is in 256 to 3600, the time unit will be minute and its value
should follow the below rules:
a), Interval time =Value/60, if the interval time can be divided by 60 and
without remainder.
b), Interval time= (Value/60) +1, if the interval time can be divided by 60 and
has remainder.
(3), Other values will be ignored.
4 (0x04)
Enable/disable the function of motion sensor.
1. Value=0, disable.
2. Value=1, enable, the current PIR sensitivity level=1. (minimum level)
Value=2, enable, the current PIR sensitivity level=2.
Value=3, enable, the current PIR sensitivity level=3.
Value=4, enable, the current PIR sensitivity level=4.
Value=5, enable, the current PIR sensitivity level=5. (maximum level)
5 (0x05)
Which command would be sent when the motion sensor triggered.
1. Value=1, send Basic Set CC.
2. Value=2, send Sensor Binary Report CC.
39 (0x27)
Configure low battery value.
Value=10 to 50.(10% to 50%)
40 (0x28)
Enable/disable the selective reporting only when measurements reach a certain
threshold or percentage set in 41-44 below. This is used to reduce network
traffic. (0 == disable, 1 == enable)
41 (0x29)
Threshold change in temperature to induce an automatic report.
Note:
1. The unit is Fahrenheit for US version, Celsius for EU/AU version.
2. The value contains one decimal point. E.g. if the value is set to 20, the
threshold value =2.0
current temperature gap is more then 2.0, which will induce a temperature
report to be sent out.
42 (0x2A)
Threshold change in humidity to induce an automatic report.
Note:
1.
The unit is %.
2.
The default value is 10, which means that if the current humidity gap is
more than 10%, it will send out a humidity report.
Description
(EU/AU version) or 2.0
(US version). When the
Default Value
Size
0
1
240
2
5
1
1
1
20 (%)
1
0
1
20
2
10
2