Dinel CLS-23 Manual - Página 12

Procurar online ou descarregar pdf Manual para Acessórios Dinel CLS-23. Dinel CLS-23 20 páginas. Capacitive level sesors
Também para Dinel CLS-23: Manual de instruções (18 páginas)

Dinel CLS-23 Manual
Sensor for each flash of the LED switches its output on for approx. 3 ms. This period is sufficiently
short to avoid unwanted switching of relay contacts. For binary inputs, we recommend to set the
filter so as not to respond to pulses shorter than 3 ms.
Units Dinel NSSU, NDSU a NLCU with transistor switch („T") detects and transmitts these pulses
to the output.
Level state
* Variant „E" without LED state indicator
For security reasons, we recommend to set the mode O (normally open, sensor closes when immersed)
for minimum level detection. Any failure of the sensor or wiring is equally apparent as the emergency
level state. Analogously – for the maximum level detection is recommended to set the mode C (normally
closed, sensor opens when immersed).
10 .  a
ccessories
Standard
(included in the level sensors price)
• 
1pc of Magnetic pen MP–8
• 
1pc of Seal (non-asbestos)
12
Mode
Type of sensor
CLS–23_–_ _– _ –P–_
CLS–23_–_ _– _ –S–_
O
CLS–23Xi–_ _– _ –R–_
CLS–23XiT–_ _– _ –R–_
CLS–23_–_ _– _ –P–_
CLS–23_–_ _– _ –S–_
O
CLS–23Xi–_ _– _ –R–_
CLS–23XiT–_ _– _ –R–_
CLS–23_–_ _– _ –P–_
CLS–23_–_ _– _ –S–_
C
CLS–23Xi–_ _– _ –R–_
CLS–23XiT–_ _– _ –R–_
CLS–23_–_ _– _ –P–_
CLS–23_–_ _– _ –S–_
C
CLS–23Xi–_ _– _ –R–_
CLS–23XiT–_ _– _ –R–_
Optional
(for extra charge)
• 
• 
• 
• 
• 
• 
Output state
CLOSED
HIGHER
CURRENT
OPEN
LOWER
CURRENT
CLOSED
HIGHER
CURRENT
OPEN
LOWER
CURRENT
Extra cables (over the standard length 2 m)
Non-rewirable connector plug M12                 
("N" and "NT" variants)
Rewirable connector plug M12                      
("N" and "NT" variants)
Steel or Stainless steel welding flange
Stainless steal fixing nut UM–18x1,5
Other seals (PTFE, Al, etc.)
LED indicator *
           (Shine)
            (Dark)
            (svítí)
          (nesvítí)
CLS–23
© Dinel, s.r.o.