Aeotec MULTISENSOR 6 Manual
send out a notification report (the previous event
Removing your Sensor from your Z-Wave network.
cleared or the absence of water event is triggered)
Your sensor can be removed from your Z-Wave
to your home gateway or the associated devices.
network at any time. You'll need to use your Z-Wave
network's main controller/gateway. To do this,
please refer to the part of their respective manuals
that tell you how to remove devices from your
network.
Water
1.
Turn your primary controller into device removal
mode.
2.
Take the Sensor unit near to your primary
(Water recedes from Sensor)
controller.
4
Advanced.
3.
Press the Action Button on your Sensor.
4.
If your Water Sensor is successfully removed
Send a wake up notification.
from the Z-Wave network, the RGB LED
In order to send your Sensor new configuration
will become a colourful gradient for a few
commands from your Z-Wave controller or
seconds and then turn off. If the removing was
gateway, it will need to be woken up.
unsuccessful, the blue LED will be solid for 2
1.
Press the Action Button on the Sensor unit and
seconds and then turn off, repeat the above
then release the Action Button. This will trigger
steps.
and send a wake up notification command to
Security or Non-security feature of your Sensor in
your controller/gateway.
Z-Wave network.
2.
If you want your Sensor to keep awake for a
Including Water Sensor as a non-secure device:
longer time, press and hold the Action Button
If you want your Sensor as a non-security device
on the back of the Sensor unit for 3 seconds,
in your Z-Wave network, you just need to press the
then your Sensor will wake up for 10 minutes
Action Button once on Water Sensor when you use
and the orange LED will fast blink while it is
a controller/gateway to add/include your Sensor.
awake.
The green LED will be on for 2 seconds and then
colourful gradient to confirm a success.
the orange LED will fast blink for 10 minutes (if the
Your Sensor's battery.
Sensor does not receive the Wake Up No More
Your Water Sensor has a internal lithium battery
Info command from primary Controller) to indicate
that will last about 2 years when it is in normal
the inclusion is successful.
use condition. If you find the Water Sensor's
Including Water Sensor as a secure device:
battery is drained, you will need to replace it with
In order to take full advantage of all functionality
a new CR123A battery, refer to the below steps to
the Water Sensor , you may want your Sensor
replace the battery:
is a security device that uses secure/encrypted
message to communicate in Z-wave network, so
1.
Unscrew the 2 screws from the Sensor.
a security enabled controller/gateway is needed
for the Water Sensor to be used as a security
device. You need to press the Sensor's Action
Button 2 times within 1 second when your security
controller/gateway starts the network inclusion.
The blue LED will be on for 2 seconds and then
the orange LED will fast blink for 10 minutes (if the
Sensor does not receive the Wake Up No More
Info command from primary Controller) to indicate
the inclusion is successful.
Factory reset your Sensor.
If your primary controller is missing or inoperable,
2.
Separate the battery cover from the Sensor
you may wish to reset all of your Water Sensor's
unit.
settings to their factory defaults. To do this, press
If you have a hard plastic board( about 0.8 to
and hold the Action Button for 20 seconds and the
1.0mm thickness) on hand, you can use it to
green LED will be solid for 2 seconds and then be
separate the battery cover directly:
Push or move the plastic board along the gap
b.
Push or move your fingernail along the gap
between battery cover and Sensor unit, refer to
between battery cover and Sensor unit, as
the direction of arrows, see the figure below:
below:
3.
Battery cover is separated from the Sensor unit.
You can also open the battery cover through your
fingers if you are confident about this way.
Find the position of the screw side, see the
operating steps below:
a.
Pull open a small gap between the battery
cover and Sensor unit.
Battery
Sensor unit
5
Technical specifications.
7
Model number: ZW122.
Power supply: CR123A lithium battery, 3V,
1500mAh.
Operating temperature: 0°C to 40°C.
Storage temperature: -20°C to 60°C.
Water proofing: IP65.
Max volume of buzzer: 60dB at 2 meters away.
Operating distance: Up to 100 feet/30 metres
indoors or 492 feet/150 metres outdoors.
6
Warning.
Do not dispose of electrical appliances as
unsorted municipal waste, use separate collection
facilities.
Contact your local government for information
regarding the collection systems available.
Battery cover
Version: 501012200001-AA
Certifications (regional):
Z-Wave and Z-Wave Plus
are registered trademarks
of Sigma Designs and its
subsidiaries in the United
States and other countries
FCC ID: XBAFT122
www.aeotec.com