Aeotec ZWA039 Manual de início rápido - Página 4
Procurar online ou descarregar pdf Manual de início rápido para Sensores de segurança Aeotec ZWA039. Aeotec ZWA039 12 páginas. Temperature & humidity sensor
respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action
right on the device.
Inclusion
1. Insert the battery.
2. Press the button quickly three times in a row.
Exclusion
1. Press the button quickly three times in a row.
Product Usage
Once the device is powered up it will start monitoring the air parameters and warn of mould using the
local red and green LED. Pushing the button will force an immediate measurement and the LEDs will
indicate the danger of mould.
green: no danger of mould in the room
red: danger of mould, open the windows to lower the humidity
The device contains two sensors with the following accuracy measures:
Relative Humidity: precision ± 3% RH (max), range 0 to 80% RH
Temperature: precision ±0.8 °C (max), range -10 to 65 °C
Dew Point: precision ±0.8 °C (max), range -10 to 65 °C (calculated from other sensor values)
The device sends the following notifications to the central controller:
Weather Alarm - Moisture Alarm (0x10 - 0x02)
Power management - Replace battery now (0x08 - 0x0b)
Heat Alarm - Overheat Unknown Location (0x04 - 0x02)
Heat Alarm - Underheat Unknown Location (0x04 - 0x06)
For getting the status of the device on the network you need insert a battery to device. And you see
result: - "The GREEN LED will blink one time in case of success or RED LED will blink five times in case of
failure".
Quick trouble shooting
Here are a few hints for network installation if things don't work as expected.
1. Make sure a device is in factory reset state before including. In doubt exclude before include.
2. If inclusion still fails, check if both devices use the same frequency.
3. Remove all dead devices from associations. Otherwise you will see severe delays.
4. Never use sleeping battery devices without a central controller.
5. Don
t poll FLIRS devices.
'
6. Make sure to have enough mains powered device to benefit from the meshing