Troubleshooting

One day your dryer seems not to be working. Before you call your Service Centre (see Service), go through the
following troubleshooting suggestions.
Problem:
The dryer won't start
Drying cycle will not begin.
It is taking a long time to dry
The water full icon
is
flashing and
displayed
but the dryer has only been
running for a short period.
Empty water icon
is on and
the water container is not full.
The Display shows a fault
code F followed by one or two
numbers
Programme finishes and
clothes damper than expected
{PDF Created 18/01/13 22:28:00}
Possible causes / Solutions:
• The plug is not plugged into the socket, or not making contact.
• There has been a power failure.
• The fuse has blown. Try to plug another appliance into the socket.
• You are using an extension cord. Try to plug the dryer's power cord
directly into the socket.
• The door is not closed securely.
• The PROGRAMMES knob has not been set properly (see Start and
Programmes).
• The START button has not been pressed (see Start and Programmes).
• You have set a delay time (see Start and Programmes).
• The filter has not been cleaned (see Maintenance).
The water container needs emptying... The 'water Container full icon'
flashing, The display shows
Maintenance).
• The condenser needs cleaning (see Maintenance).
• The temperature setting is not ideal for the type of fabric you are
• drying (see Start and Programmes, and Laundry ).
• The correct drying time has not been selected for this load
(see Laundry).
• The air intake grille is obstructed (see Installation and see Maintenance).
• The items are too wet (see Laundry).
The dryer is overloaded (see Laundry).
• The water container was probably not emptied at the start of the programme.
Do not wait for the empty water signal always check and empty the container
before starting a new drying programme. (see Maintenance).
This is normal if the light is on its just a reminder to empty the container. (see
Start and Programmes)
• If the display shows a fault, Turn off and remove plug, Clean the Filter and
Condensing Unit (see Maintenance). Then replace plug turn on and start
another program. If a fault is then displayed. Note down the number and
contact the service centre (see Service)
! For safety the dryer has a maximum programme time of 4 hours. If an
automatic programme has not sensed the required final moisture in this time the
dryer will complete the programme and stop. Check the above points and run the
programme again, if the results are still to damp, contact the service centre (see
Service).
16
and the empty water icon
is on.