ALCON Manor-2101 Manual de início rápido

Procurar online ou descarregar pdf Manual de início rápido para Sistemas de controlo ALCON Manor-2101. ALCON Manor-2101 2 páginas.

Manor-2101
0–10 V-
Ballast or LED Driver Control
Compatible with any LED driver or ballast
that is compliant with IEC 60929 annex E
120 – 277 V ~ 50 / 60 Hz
Maximum Capacity
Load
0 – 10 V - Sink
8 A
30 mA
For use with 0 –10 V - Electronic
Fluorescent Dimming Ballasts or
LED Drivers
Package Contents and Parts Identification
Control Wires
(Violet and Gray)
Control
Wallplate Adapter
Switching Wires
(Black)
Control-Mounting Screws
Adapter-Mounting Screws
Important Notes
Please Read Before Installation
Wallbox Dimensions: A single-gang wallbox (3 in high × 2 in wide ×
individual controls.
Derating Instructions:
No derating required for multi-gang
installations.
Wiring Note: Always turn OFF power before installation. Install in
accordance with all national and local electrical codes.
Lamp Seasoning Requirements:
rescent lamp
manufacturers r
rescent lamps be operated
at full output (seasoned) before they can be dimmed, to render lamp
impurities inert, ensuring proper dimming performance and average
rated lamp life. Please contact your lamp manufacturer for seasoning
requirements.
Ballast/Driver Functionality Check:
With power OFF, check new
ballast for functionality prior to installation of control by connecting
the ballast's violet and gray wires together at the control. Turn power
on. The lights should now be at minimum brightness. With power OFF,
disconnect the wires. Turn power ON. The lights should now be at
maximum brightness.
Cleaning Instructions:
Clean dimmer with a soft damp cloth only.
Do not use any chemical cleaners.
Use this product only as intended with recommended accessories.
Control Unit
Front view
Wire Connectors
O
holes
Slider
Wallplate
Center-mounting holes
AlconLighting.com © 2013
2845 S. Robertson Blvd. Los Angeles, CA 90034 USA
Pre-Installation
Determine if this will be a multi-gang installation or a single -gang installation.
If using a multi-gang installation, before proceeding to the Installation section, follow the Multi-gang Installation
procedure and refer to the instruction sheet supplied with multi-gang wallplates.
If using a single-gang installation, install control as outlined in the Installation section.
Multi-gang Installation
In multi-gang installations, several controls can be grouped horizontally in one ganging wallbox or in a series of
connected wallboxes. Multi -gang wallplates are available to simplify and improve the appearance of an installation.
For retrofit installations, the side sections can be removed to fit existing wallboxes.
No Side Sections Removed
1. Determine the number of wallboxes necessary by
using the chart below. Use 3 in × 2 in (76 mm × 51 mm)
gangable wallboxes. Do not use plaster rings or gangbox
covers.
Number of Controls
1
2
Wallboxes
1
1 + 1
2. Install or modify appropriate wallboxes. For an EVEN
number of controls, wallboxes must be 3/4 in (19 mm)
apart to provide necessary space for the wallplate(s). For
example, when ganging four controls, three would be
in the four connected wallboxes and one would be in a
wallbox separated by the required space.
Four-gang
gangable
wallbox
3. When mounting controls, use center-mounting holes
Low-end
rol and o
-mounting holes for additional
trimpot
shaft
High-end
trimpot
shaft
(877)733-5236 | [email protected]
Side Sections Removed
Note: No derating required
1. One gangable wallbox is needed for each control
in the multi-ganged control. Individually connect
wallboxes or use a pre -assembled, multi-gang
wallbox.
3
4
5
6
2. Remove only inner side sections of control. Use pliers
4
4 + 1
7
7 + 1
to bend side sections down as far as you can then
back to their original positions. Side sections will
break o
Single-gang
Note: Do not remove outer side sections of the two
gangable
wallbox
controls that are on the ends of the gang.
3. When mounting, use center -mounting holes for
proper alignment.
3/4 in (19 mm)
(use chase nipple)
Multi-ganged
controls,
no side sections
removed
English
Multi-ganged
controls,
inner side
sections
(indicated
by shading)
removed