Acond Hydromodul HM Manual de instalação - Página 9

Procurar online ou descarregar pdf Manual de instalação para Aquecedor de água Acond Hydromodul HM. Acond Hydromodul HM 17 páginas.

Hydromodul

6.1.1 Electrical preparation

The electrical connection is made from the bottom side, where leave a free cable length of at
least 2m. The cables to be brought in are given by the diagrams annexed to this document.

6.2 Indoor room unit

The indoor C-ID room unit shall be placed in a heated reference room. The heating rod will be
switched if the temperature in the reference room unit drops below the set temperature in the
AcondTherm regulation.
A thermostatic valve shall not be placed in the reference room.

7 Installation

When installing, follow the order as shown below.
7.1 Mounting of the attached assembly
Attach the included assembly with pliers above the Hydromodule covers, see the following
picture. Use the seal correctly.
Installation manual
8