Internal Programming Jumper

Important: The module must be unscrewed to access the light flash jumper.

Light Flash

This jumper is used to determine the light flash output. In the (+) position, the
on-board relay is enabled and the unit will output (+)12V on the H1/2 WHITE
wire. In the (-) position, the on-board relay is disabled. The H1/2 WHITE wire
will supply a (-) 200 mA output suitable for driving factory parking light relays.
To access the jumper, open the control module.
Important:
For parking light circuits that draw 10 amps or more, the internal
P/N 8617
jumper must be switched to a (-) light flash output.
or a standard au-
tomotive SPDT relay must be used on the H1/2 light flash output harness wire.