Maintenance
[See Figure 3 for all item numbers referenced below]
1. Turn OFF the electrical supply.
2. Drain the pump body by removing the drain plug (Item No.
2)
3. Unscrew the 6 bolt (Item No. 4) that fi x the pump body
(Item No. 1) to the pump support (Item No. 12) remove
the pump body. If the body is stuck you can gently insert
a screw driver between the pump body (Item No. 1) and
pump support (Item No. 12) and pry apart..
4. Remove the 1 retaining screw that holds the fan cover (Item
No. 33) in place. Then slide the fan cover (Item No. 33)
from the motor casing (Item No. 18).
Revision (7-12)
5. Once the fan cover is removed the fan (Item No. 32) can
then be removed from the Shaft (Item No.17)
6. The shaft (Item No. 17) can then be gripped so that the im-
peller (Item No. 10) can be unscrewed giving access to the
mechanical Seal (Item No. 11). The rotary part will stay on
the impeller (Item No.10) and the static part will be retained
in the pump support (Item No. 12).