Directed Electronics Xpresskit SoleX Series Manual de instalação - Página 7

Procurar online ou descarregar pdf Manual de instalação para Acessórios para automóveis Directed Electronics Xpresskit SoleX Series. Directed Electronics Xpresskit SoleX Series 9 páginas.

The Mobile Integration Systems
Platform: XK09
Firmware: CHRYSLER3

LED Diagnostics and Troubleshooting

LED
Status
Module Programming
Off
Off
Solid
Solid
Flashes quickly
Flashes
Solid x3 seconds
Solid
x3 secs
then OFF
Flashes once
Flashes
1x
quickly
Flashes twice
Flashes
2x
pattern
Active Ground While Running
Solid
Solid
Off
Off
Flashes for
Flashes
x1 sec
1 second
Flashes
Flashes
Inactive Ground While Running
Off
Off
Flashes for
Flashes
x1 sec
1 second
Solid
Solid
Flashes
Flashes
Description
Module has no power.
Data Bus is not detected.
Module has detected IGN
ON. Waiting for VIN
information.
Module is programmed.
Module was reset.
VIN invalid.
Incorrect behavior.
Ground While Running
(status) OFF.
A command is processing.
Ground While Running
(status) ON.
Ground While Running
(status) OFF.
A command is processing.
Incorrect behavior.
Ground While Running
(status) ON.
Troubleshooting
Verify your powerlines (D2D or W2W).
Make sure the connections of the CAN Bus are correct,
then press the Push-to-Start (PTS) button twice to turn
the ignition ON.
Normal operation.
Normal operation.
Normal operation.
Contact tech support.
Data is not processing correctly. Disconnect the power
from the module and power up.
Make sure the module was programmed, i.e. the D2D
harness is properly connected or the Ground While
Running (status) wire is connected (if in W2W mode).
Normal operation.
Normal operation.
Normal operation.
Normal operation.
Data is not processing correctly. Disconnect the power
from the module and power up.
Module did not receive ground while running (status)
OFF. Make sure the D2D harness is properly
connected or the ground while running (status) wire is
not shorted to ground.
© 2011 Directed Electronics. All rights reserved.
Rev.: 20111122
Page 7