Aroma360 HOTEL SCENTS MUSEUM360 Manual de início rápido

Procurar online ou descarregar pdf Manual de início rápido para Acessórios Aroma360 HOTEL SCENTS MUSEUM360. Aroma360 HOTEL SCENTS MUSEUM360 2 páginas.

Aroma360 HOTEL SCENTS MUSEUM360 Manual de início rápido
At a Glance
LCD Screens — The Museum360 has two LCD screens to o er
dual-scenting power.
POWER — The unit has three power buttons. The center switch underneath
the LCD screens turn on the unit. The individual switches underneath the
LCD screens power the corresponding sides of the Museum360.
LOCK SETTINGS — If you want to lock the settings to prevent tampering,
hold down the SET button for 20 seconds. This will prevent anyone from
adjusting the settings on the unit. You will hear a beep that confirms the
settings have been locked. Repeat to unlock the settings. You will need to
unlock the unit to adjust the settings.
FACTORY RESET — If you want to reset the unit to the factory settings,
hold down the MODE button for 20 seconds and the unit will return to the
original settings.
HVAC CONNECTION — Your Museum360 is meant to be used in
conjunction with the central air conditioning system.
Understanding Your Museum360
The Museum360's LCD display provides valuable information about your
settings. Here is a quick guide on what each item means.
WORK/PAUSE — When the unit is in WORK mode, it is emitting aroma.
When the unit is in PAUSE mode, it is not emitting aroma.
TIME — The number displayed on the unit should represent the current time,
using the 24-hour clock.
DAY OF THE WEEK — The Museum360 allows you to have di erent settings
for multiple days. The day that's shown on the display should be the current
day.
SCENT/WORK/PAUSE — This screen appears when adjusting the scenting
strength.
What's included:
The Museum360 Di user Unit
1 or 2 Empty Aluminum Bottles
1 or 2 Atomizers with Attached
Wall-Mountable Plate
Power Cord
Thick Transparent Tubing
Thin White Tubing
Wall Mounting Brackets
Spare Nozzle
Setting Up Your Museum360
1
Unbox your di user to reveal your new Museum360. Familiarize yourself with
the parts and accessories.
Connect the 10A-125V power cord to the di user and plug it into a regular
2
110v outlet. Press the center button to power the unit on. Press the switch
underneath the LCD screen to power on the individual sides. Turn both sides
on if you are using the Museum360 as a Double.
Now that the di user is powered on, you may begin adjusting the settings to
your liking. By default, the LCD screen will depict the current time. Note the
unit uses a 24-hour clock so 5:30pm will be shown as 17:30
Installing your Museum360
1
Ensure that your di user is powered o and unplugged. A ix the provided
wall plate and atomizer as close to the ductwork as possible. Unscrew the
bottle from the wall plate and atomizer. Pour in your Aroma360 fragrance oil
and tightly screw the bottle back into place.
2
Insert one end of the thin white tube into the hole on the back of the di user
on the side you have set and are prepared to use. Insert the other end into
the top of the atomizer. Cut away any excess tubing.
3
Just after your HVAC filter, use a screwdriver or a drill to make a small hole
(or two if you are installing a Double Museum360) in the ductwork. These
scent points should be the same diameter as the thick transparent tube.
4
Insert one end of the thick tube about 6" into the scent hole and the other
end into the larger hole at the top of the atomizer. Cut away any excess
tubing and seal the scent point (see below) with HVAC tape. Ensure your
tubing is vertical and not horizontal.
5
Plug in and turn on your di user to begin enjoying your consistent scenting
experience.
Setting the Current Time
1
To set the current time, press SET and the hour will flash. Press UP or DOWN
to adjust to the current hour and press SET to confirm your choice. (If your
screen is unresponsive, press and hold the SET button for 20 seconds).
2
The minutes will now be flashing. Press UP or DOWN to adjust to the current
minute and press SET to confirm your choice.
3
The day of the week will now be flashing. Press UP or DOWN to adjust to the
current day of the week and press SET to confirm.
-- : --
MODE
SET
UP
DOWN
MODE
SET
Setting the Operating Hours
Now it's time to set your scenting events. The Museum360 allows up to five
individual events to scent at di erent times throughout the days of the week.
1
To set the start time of an operating period: Press MODE. EVENT 1 ON will
appear. This represents the On Time for the first working period. Set time as
instructed above.
2
To set the operating days: Press UP or DOWN. The days of the week will
begin to flash. Select the days you wish to apply the working hours to. Once
the desired days have been selected, press SET to confirm.
3
To set the end time of the operating period: Press MODE. EVENT 1 OFF will
appear. This represents the O Time for the first operating period. Press UP
or DOWN to adjust the hour, press SET to confirm. Repeat to set the
minutes.
4
Repeat these steps to set Events 2-5, if need be.
Ensure there are no conflicting settings.
The unit cannot be set to run past midnight. You must split the setting
between two di erent working periods. For example:
i. EVENT 1 ON — 22:00 EVENT 1 OFF — 23:59
ii. EVENT 2 ON — 00:01 EVENT 2 OFF — 04:00
How to Adjust the Scent Intensity
1
Press MODE and the display will show SCENT WORK PAUSE. This is
where you will adjust the scent intensity for EVENT 1. You can set it
between 5% and 95% (with 5% being the lowest setting and 95% being
the highest setting). Press SET to confirm the intensity.
2
Once you have the desired scent intensity, press MODE and EVENT 2 ON
will appear. This will allow you to set the On Time for the second and
remaining EVENTS. If you only have one EVENT, then press MODE until
you reach the end of the event settings.
: 00
UP
DOWN