Move the heatbed slowly to the front to such position that the hotend is above the front left corner of the heatbed
– be careful so the heatbed do not hit the hotend (hotend should be a few milimeters above the heatbed).
10
Adjust the distance between the nozzle and the heatbed with the knurled bolt to 0.8 mm by following steps:
– check the distance between the nozzle and the heatbed using a feeler (or typical credit card). It should be 0.8 mm,
– when the distance is more or less than 0.8 mm, adjust it manually using the knurled bolt – turn the knurled bolt
in the appropriate direction (we recommend not more than a half of turnover – for safety),