Conditions necessary for circuit to work
1. Battery voltage
2. Key switch on
3. CB-4&5 closed
4. Solenoid 5 closed in rev.
5. Solenoid 6 closed in forward.
6. Solenoid 2A closed when not in neutral andbrushes down with battery voltage above 31.5(CCV)
7. Seat switch closed
1
1T
12
11
(B+)
12
1,1A,1B
25
BATT.
CB-4
25F
10 AMP
IGN.
25G
2
3
ACC
3
CB-5
3A
10 AMP
T0207/0002
TO THROTTLE
CONTROL UNDER
American-Lincoln Technology
ENCORE R Troubleshooting Guide

SCRUB BRUSHES CIRCUIT

A
CB-2
2A
45 AMP.
K
G
E
E
J
CB-3
45 AMP.
NEW MODULE
4
3
36
26
33
25G,H,J
RAISE
36
OFF
28
7D,7E
25F
OFF
27
26
BRUSH
DECK
BRUSH DECK
SWITCH
ACTUATOR
FOOT PEDAL
36 V BATTERY BANK
SCRUB BRUSH
MOTORS
300 RPM
77A
2
1
7
6
5
16
11
11A
28 27
34
35
RED
YEL
10B
11
10,10A
9B
9A
1207-1135
9A
16
CONNECTOR
8
T207
SCRUB BRUSHES CIRCUIT
7,7C,7H,
B
77,77C,77D
77B
31
7G
UP
R
8
7F,7G
30
DOWN
9
Y
LOADED
7E,7F
29
10
DOWN
G
7A,7B
15
13
(B-)
SCRUB BRUSH SOL.
13
REV. MTR. SOL.
17
5
FWD. MTR. SOL.
6
18
9
10
9
1
17
18
7A,7B
7,7A
2A
7K
1-9