Conditions necessary for circuits to work:
1. Battery voltage
2. Key switch on
3. CB-5&6 closed
4. Horn button depressed (for horn only)
5. Seat switch closed for hour meter to work
1,1A1B
KEY SW.
ACC.
3A,3B,3C
T0205/0002
American-Lincoln Technology
ENCORE R Troubleshooting Guide

HORN, HOUR AND CONDITION METER CIRCUITS

HORN, HOUR AND CONDITION METER CIRCUITS
36V BANK
1T
12
11
(B+)
12
CB-5
10 AMP.
8
CB-6
10 AMP.
NEW MODULE
4
3
7
11A
HM
8
CM
HORN
SW.
1D
T205
6
5
2
1
16
15 14
11
11A
7L,7M
HORN
1E
8
9
10
17
13
7L
77D
1-7