Procurar online ou descarregar pdf Manual de início rápido para Unidade de controlo Camille Bauer SIRAX B 811. Camille Bauer SIRAX B 811 10 páginas. Plug-in module power pack with additional functions
Plug-in Module SIRAX B 811
Power Pack with Additional Functions
Current limiter:
Max. line resistance:
Measuring output
Output signals A1 and A12
(see Section "Electrical connections")
The output signals A1 and A12 can be load-independent DC
voltages U
or currents I
.
A
A
A1 and A12 are not electrically insulated; the same value is avail-
able at both outputs.
DC voltage signals U
A
Standard ranges for U
:
A
Non-standard ranges:
Short-circuit current:
Load capacity U
/U
:
A1
A12
Load impedance U
/U
:
A1
A12
Residual ripple:
DC current signals I
A
Standard ranges for I
:
A
Non-standard ranges:
Open-circuit voltage:
Burden voltage I
:
A1
*When a hand-held terminal is connected to the field output A12,
the voltage across the burden at output A1 reduces to 10 V. Dig-
ital communication requires a minimum burden at output A1 of
250 Ω. A 250 Ω resistor is therefore connected across the output
circuit. If the load of the burden across output A1 already exceeds
250 Ω, the resistor can be disconnected by changing the position
2
Electronic
At I
> 30 mA, U
is switched to 0 V
E
S
for approx. 1 s.
U
is then automatically readjusted
S
to its set-point
The maximum line resistance R
permissible between the 2-wire
transmitter and the supply unit
depends on the voltage difference
U
– U
:
S
M
U
– U
S
M
R
max. =
Ltg
20 mA
U
= Supply voltage for
S
2-wire transmitter
U
= Min. operating voltage of the
M
2-wire transmitter
0...5, 1...5, 0...10 or 2...10 V
0...> 5 to 0...15 V
resp. live-zero
> (1...5) to 3...15 V
≤ 40 mA
20 mA
U
[V]
A
R
// R
[kΩ] ≥
ext A1
ext A12
20 mA
< 1% p.p., DC ... 10 kHz
0...20 mA or 4...20 mA
selected by jumpers
0...1 to 0...< 20 mA
resp. live-zero
0.2...1 to < (4...20) mA
Approx. – 7...+ 22 V
15 V without communication
10 V (15 V) with communication*
Data sheet B811-6 Le – 09.07
of the jumpers J 204 and J 205. The full burden voltage of 15 V
is then available at output A1 instead of 10 V.
External resistance I
A1
line
Burden voltage I
:
A12
External resistance I
A12
Residual ripple:
Response time (IEC 770):
Output characteristic:
Power supply H
AC/DC power pack (DC and 45...400 Hz)
Table 1: Nominal voltages and tolerances
Nominal voltage
U
N
24... 60 V
DC / AC
85...230 V
1
DC / AC
24... 60 V
DC / AC
85...230 V AC
85...110 V DC
For power supplies > 125 V, the auxiliary circuit should include an external
1
fuse with a rating ≤ 20 A DC.
Power input:
Communication
Bi-directional communication of digital signals with an "intelligent"
2-wire transmitter designed for FSK and a HART or company-
specific protocol.
Frequency range:
Input circuit monitor
Pick-up level:
15 V (10 V)
:
R
max. [kΩ] =
ext
I
I
= Output circuit full-scale value
AN
< 0.3 V (field indicator)
0.3 V
:
R
max. [kΩ] =
ext
I
AN
< 1% p.p., DC ... 10 kHz
Approx. 200 ms
Linear
Tolerance
DC – 15...+ 33%
AC ± 15%
DC – 15...+ 33%
AC ± 15%
± 10%
"Intrinsically safe"
[EEx ia] IIC
– 15...+ 10%
Approx. 2.5 W resp. ≤ 4.5 VA
500 Hz ... 35 kHz
– Open-circuit
Input current < 3.6 mA,
adjustable in the works between
1 to 4 mA
– Short-circuit
Input current > 21 mA
adjustable in the works between
20 to 23 mA
[mA]
AN
[mA]
Instrument
version
Standard
(non-Ex)
Type of
protection
Camille Bauer