Procurar online ou descarregar pdf Manual de instruções para Aspirador de pó Alton DW18903PR-6H. Alton DW18903PR-6H 12 páginas. 6gallon (23 l) portable wet/dry vacuum
English
as described under Wet Pickup Applications.
• Some wood contains preservatives which can be
toxic. Take extra care to prevent inhalation and skin
contact when working with these materials. Request
and follow any safety information available from the
material supplier.
• Do not use vacuum as a step ladder.
• Do not place heavy objects on vacuum.
• An extension cord must have adequate wire size
(AWG or American Wire Gauge) for safety. The
smaller the gauge number of the wire, the greater
the capacity of the cable, that is 16 gauge has
more capacity than 18 gauge. An undersized cord
will cause a drop in line voltage resulting in loss of
power and overheating. When using more than
one extension to make up the total length, be sure
each individual extension contains at least the
minimum wire size. The following table shows the
correct size to use. If in doubt, use the next heavier
gauge. The smaller the gauge number, the heavier
the cord.
• If an extension cord is to be used outdoors it must
be marked with the suf x W-A or W following the
cord type designation. For example – SJTW-A to
indicate it is acceptable for outdoor use.
Minimum Gauge for Cord Sets
Volts
Total Length of Cord in Feet (meters)
Ampere Rating
120V
25 (7.6)
240V 50 (15.2) 100 (30.5) 200 (61.0) 300 (91.4)
More
Not More
Than
Than
0
6
18
6
10
18
10
12
16
12
16
14
WARNING:
Always wear proper personal hearing
protection that conforms to ANSI S12.6 (S3.19)
during use. Under some conditions and duration of
use, noise from this product may contribute to
hearing loss.
WARNING:
ALWAYS use safety goggles. Everyday
eyeglasses are NOT safety goggles. Also use face or
dust mask if area operation is dusty.
ALWAYS WEAR CERTIFIED SAFETY EQUIPMENT:
• ANSI Z87.1 eye protection (CAN/CSA Z94.3),
• ANSI S12.6 (S3.19) hearing protection,
• NIOSH/OSHA/MSHA respiratory protection.
WARNING :
This product can expose the to
chemicals including lead, which is known to the
State of California to cause cancer, birth defects or
other reproductive harm. For more information
go to www.P65Warnings.ca.gov.
To reduce your exposure to these chemicals, wear
approved safety equipment such as dust masks that
are speci cally designed to lter out microscopic
particles. For your convenience and safety, the
following warning labels are on your vacuum.
ON MOTOR HOUSING :
WARNING:
• TO REDUCE THE RISK OF INJURY, USER MUST READ
INSTRUCTION MANUAL. DO NOT RUN UNATTENDED. DO
NOT PICK UP FLAMMABLE, COMBUSTIBLE OR HOT
50 (15.2) 100 (30.5) 150 (45.7)
AWG
16
16
14
16
14
12
16
14
12
12
Not Recommended
MATERIALS. DO NOT USE AROUND EXPLOSIVE DUST,
LIQUIDS OR VAPORS. ELECTRICAL DEVICES PRODUCE
ARCS OR SPARKS WHICH CAN CAUSE FIRE OR
EXPLOSION. DO NOT USE AT FILLING STATIONS OR
ANYWHERE GASOLINE IS STORED OR DISPENSED. DO
NOT VACUUM TOXIC OR CARCINOGENIC MATERIALS OR
OTHER HEALTH ENDANGERING MATERIAL SUCH AS
ASBESTOS OR PESTICIDES. ALWAYS USE PROPER EYE
AND RESPIRATORY PROTECTION. TO REDUCE THE
RISK OF ELECTRICAL SHOCK, DO NOT EXPOSE TO RAIN.
STORE INDOORS. WHEN SERVICING, USE ONLY
IDENTICAL REPLACEMENT PARTS. NOT TO BE USED AS
A STEP STOOL.
OPERATING INSTRUCTIONS
UNPACKING & SET-UP SUMMARY
1.Pull lid latches in an outward motion, remove power
head and some accessories that may have been
shipped in the tank.
2.Attach heavy-duty rubberised casters following the
instructions in this manual.
3.Before replacing power head, refer to this manual to
ensure you have the proper lters installed for your
cleaning operation.
4.Replace power head, and apply pressure with thumb
to each latch until it snaps tightly in place. Make sure
all lid latches are clamped securely.
5.Insert the air hose end into inlet of tank.
6.Attach the extension wands to the accessory end of
the hose. Apply slight pressure until tting is tight.
7.Attach one of the cleaning accessories (depending
on your cleaning requirements) on the extension
wands. Twist slightly to tighten the connection.
8.Plug the cord into the wall outlet. Your cleaner is
ready for use.
WARNING:
To reduce the risk of re or explosion, do not operate
this vac in areas with ammable gases, vapors or
explosive dust in the air. Flammable gases or vapors
include but are not limited to: lighter uid, solvent-type
cleaners, oil-based paints, gasoline, alcohol or aerosol
sprays. Explosive dusts include but are not limited to:
coal, magnesium, aluminum, and grain or gun powder.
Do not vacuum explosive dust, ammable or
combustible liquids or hot ashes. Do not use this vac
as a sprayer for any ammable or combustible liquid.
To reduce the risk of health hazards from vapors or
dusts, do not vacuum toxic materials.
IMPORTANT SAFEGUARDS
The symbol on the product or packaging indicates that
the product must not be treated as domestic refuse.
Instead, it should be handed in to a collection point for
the recycling of electrical and electronic components.
By ensuring the product is treated in the correct manner,
you will help prevent any negative impact on your health
and the environment that might arise were the product
to be discarded as ordinary refuse. For further information
about recycling, you should contact your local authorities,
refuse collection service or the sales outlet where you
bought the goods.
4