Internet Settings
APN Access Point (ask your mobile provider)
APN User Name (ask your mobile provider)
APN Password (ask your mobile provider)
Internet-application server's IP address
Internet-application server's port
Number of attempts to establish GPRS before reconnect COUNT1:3
Number of attempts to establish TCP before reconnect
Ping frequency in home network, 1-99 sec
Ping frequency in roaming, 0-99 sec (0-OFF)
Tracking mode (committing routes to the system)
Note: after the setting of the APN point, ALTOX module will switch into
GPRS mode. Internet traffic amounts to less than 3MB/month without
rounding off (TRACKING0), in TRACKING1 mode - less than 30MB/month.
Settings for the TRACKING1 mode
Switching threshold moving/parking, km/h
Transmission frequency in motion (0-50km/h), 1-99sec
Transmission frequency in motion (50-100km/h), 1-99s
Transmission frequency in motion (>100 km/h), 1-99sec FREQ3:15
Transmission frequency when parked, 0-9999sec (0-OFF) FREQ4:60
Transmission frequency in motion (roaming), 0-999sec
Transmission frequency when parked (roaming), 0-9999s ROAM2:600
Text SMS with General Settings:
A0 R1 B0 T30,0,0
- HEATER-A0, RSTOP1, BIND0, TIME1/2/3
E10 L0,0,0 F0
- ERRCTRL:10, LTEMP1/2/3, FIXKEY0
P0 S0,0 K0
- PULSEOUT:0, SEPAROUT0, SEPARLINE0, KEEPOUT0
S1:w0,e1,v11.0,t99 - SMSF1, SMSW0, SMSE1, SMSV:11.0, SMST99
C1 P""
- CALL1, PASS: (up to 4 characters)
N1""/N2""/N3""
- NUM1, NUM2, NUM3 - phone numbers cells
B"*100#":10,5:1
- BAL:*100#, BTIMER1:10, BTIMER2:5, TRANSLIT1
Text SMS with ID and Internet Settings:
ID:12345678901234 - Unique Device Identificator
S"XXX.X.X.X","XXX" - SERVER1:XXX.X.X.X, SERVER2:XXX
G"apn","user","pass" - APN1:apn, APN2:user, APN3:pass
C3,2 P30,30, T0:10 - COUNT1/2, PING1/2, TRACKING0,TMOTION:10
F5,10,15,60 R90,90 - FREQ1/2/3/4, ROAM1/2
Text SMS with GSM Stations Data:
The text message contains 7 cells with data: N, MCC, MNC, LAC and CID.
N - number of cell from 0 to 6 (if a cell is empty, all fields have value 0),
MCC - country code, MNC - network code, LAC -local area code, CID - cell
ID. LAC and CID fields values are displayed in hexadecimal notation.
Following voice prompts you should enter a DTMF-command by pressing a
Command
relevant tone button:
APN1:internet
- Switching the autonomous heater ON/OFF – press 1.
APN2:login
- Request account balance – press 2.
APN3:password
- Request heater status – press 3.
SERVER1:X.X.X.X
After a minute the connection is dropped automatically.
SERVER2:XXX
The parking heater will be ON for the specified in settings time period
(TIME1), and additionally LED on the button installed in the car will be
COUNT2:2
activated.
PING1:30
Control via Button
PING2:30
TRACKING1 /0
The standard ALTOX equipment also includes a button (it is installed if
required in the car's interior). This button controls the heater and indicates
its current working status.
Control via Internet
Command
This option allows controlling the heater in the real-time mode via
TMOTION:10
Internet-app ALTOX HEATER (http://altox.ru/app) using your phone's or
FREQ1:5
tablet's browser. Detailed recommendations on setting up the Internet-app
FREQ2:10
and switching the module to the GPRS mode can be found in the document
«Description of ALTOX HEATER Internet-application».
Attention! If you decide not to use the option of controlling the heater via
ROAM1:90
Internet after switching the module into the GPRS mode, you should switch
the GPRS mode off by sending a text message command «APN1:».
Control via SMS
Send a SMS-command to the phone number associated with the SIM card
installed in the module. Text message commands can be sent from any
phone number. If the password is set (PASS setting), then before entering
any command, you should include its value with no spaces (for example,
«1111START», where 1111 is password, START is an command).
Switch the heater ON (operation time from TIME1)
Switch the heater ON for a time period of ХХmin (10-120) START:XX
Switch OFF the heater
Request a text message (SMS) with the heater status
When setting SEPAROUT1 is activated, the auxiliary output OUT is switched
into a manual control mode (to implement additional options).
Switch ON only the auxiliary output OUT
Switch OFF only the auxiliary output OUT
Heater Control
Auxiliary Output Control
Command
START
STOP
STATUS
Command
ACTIVATE