AIMS Power CON120AC36/48VDC Manual do utilizador - Página 10

Procurar online ou descarregar pdf Manual do utilizador para Conversor de multimédia AIMS Power CON120AC36/48VDC. AIMS Power CON120AC36/48VDC 12 páginas. Ac converter / battery charger

AIMS Power CON120AC36/48VDC Manual do utilizador
If any other situations occur that are not listed above, call AIMS Power immediately.
4.

Specifications

4.
Specifications
4.1
Input
4.1
Input
Input Voltage
Frequency
Nominal Input Current at Rated
Output
Voltage Measurement Accuracy
Frequency Measurement Accuracy ±1Hz
4.2
Output
4.2
Output
Nominal Voltage
Output Current
Rated Output Current
Current Accuracy
Load Regulation
Selectable Battery Type
Parallel Outputs
Efficiency
4.3
Protection
4.3
Protection
Input Over/Under Voltage
Reverse Battery Polarity Protection
Output over voltage
Charger over temperature
protection
96-145VAC full performance
70-96VAC automatically derate to 50% of full load current
40Hz to 70Hz
<9Aac
±8Vac
36/48Vdc manual adjustable
Input voltage 96-145V,
Output current 25A for 36V mode
Output current 18.75A for 48V mode
Input voltage 70-96V,
Output current 12.5A for 36V mode
Output current 9.375A for 48V mode
Manual adjustable
± 6% of full rated output current @25°C, for target currents
across the range from 10% rated output (for absorption exit
criteria accuracy) to the current limit set point.
1.5%
Open Lead-Acid, Gel, AGM, LiFePo4 (see charging voltages)
Maximum of two AC converter units connected in parallel
80%
Unit must be safe for input voltage up to 150VacRMS (and up to 215Vpeak),
need not be operating. Above this level the unit may be damaged. Unit must not
be damaged for all input voltages from 0-300Vac. Shutdown or input current limit
or other means may be applied when input voltage is out of normal operating
range.
Non-destructive reverse battery polarity protection with fuses.
Unit will not sustain damage and will meet all specifications
after fuse replacement.
Unit will shut down if Vcharging > Vcharging (target) +
1.0Vdc/1.5Vdc/2.0Vdc/2.5Vdc for more than 2 seconds; unit will restart when
voltage <= Vcharging (target) for more than 2 seconds. For battery OVP the unit
will restart in the same stage.
The internal temperatures of the charger will be measured by
NTC. Based on these measurements, unit will shut down if the
temperature exceeds 105°C. Unit will restart when
environment temperature cools to 95 °C.
- 10 -