Alula RE118 Manual de instalação
Procurar online ou descarregar pdf Manual de instalação para Acessórios Alula RE118. Alula RE118 2 páginas. Flood & temp sensor interlogix compatible
Resolution Compatibles
Flood and Temp Sensor
It detects flood conditions and reports extreme temperatures.
Features
• Titanium probes for unmatched corrosion immunity
• IP67 rated waterproof enclosure
• GORE
vent to prevent seal failure
®
• 5 year warranty
Enroll
the flood zone by placing the panel into wireless
enrollment mode and removing the battery tabs or tampering
the sensor. The freeze and heat zones are disabled by default.
To activate and enroll the freeze and heat zones, remove the
sensor cover and use a wire or paper clip to short the desired
outer terminal to the center terminal. To maximize battery life,
only activate the zones being used.
DL ID Configuration
• Flood ID is the serial number shown on the device.
• Freeze ID is the serial number with last digit
replaced with a 1.
• Heat ID is the serial number with last digit replaced
with a 2.
Install
by placing the sensor in the location requiring flood or
temperature detection. If desired, the wall clip can be used to
secure the sensor.
Optional Screw Mounting
• Remove the wall clip from the sensor's body.
• Secure the clip to a wall, baseboard or cupboard
using a #6 screw.
• Slide the sensor's body down onto the wall clip until
it snaps into place.
Detects
water pooled under the sensor and reports extreme
temperature conditions.
Temperature Trip Points
• Heat alarms when over 100°F (38°C)
• Heat restores when under 97°F (36°C)
• Freeze alarms when under 45°F (7°C)
• Freeze restores when over 48°F (9°C)
To replace the batteries,
the front slot and twist. Slide both old batteries out and the
new batteries in. To reinstall the cover, align the rear latches
and roll the cover forward until it snaps into place.
Verify proper enrollment and operation using your control panel's installation manual.
RE118 Flood & Temp Sensor
Interlogix
®
is an integrated environmental sensor.
insert a flat blade screwdriver into
Compatible
Wall Clip
Mounting Screw Hole
Front slot
I