DRY LOCATION APPLICATIONS
1
Measure area where luminaire will be installed. Use a laser line to
create a reference line along installation area, ensuring consistent
alignment of mounting clips. Mark location where each mounting
clip will be installed along reference line.
2
Use 1 mounting clip every 2', rounded up. Use a minimum of 2
mounting clips per fi xture segment. For vertical applications, create
a stopper at the bottom of the run to prevent sliding.
3
Use a mounting clip at the junction between two fi xture segments.
Example: 20' Run.
8'
3" Gap
Mounting Clip
4
Lay mounting clips along reference line and pre-drill using an
appropriate drill bit for surface material and screw size.
Typical screw size is 8/32 x 1".
Note: Allow 1/4" clearance on each side of mounting clip due to
lateral expansion. Only install mounting clips on flat, even surfaces.
5
Screw mounting clips to surface, then snap luminaire into mounting
clips. Install set screws to each mounting clip, if applicable. Set screws
are required for downward facing, outward facing, and vertically
mounted applications.
6
Screw mounting clips to surface, then snap luminaire into mounting
clips. Install set screws to each mounting clip, if applicable. Set screws
are required for downward facing, outward facing, and vertically
mounted applications.
1170 N Red Gum St, Anaheim, CA 92806
aluz.lighting
© ALUZ All Rights Reserved. ALUZ reserves the right to make changes or withdraw specifi cations without prior notice.
A1 Series | Surface
ZIBI Standard Dynamic White
(A1-ZIBI-STN-DWH)
20'
8'
4'
Junction between luminaire segments
866.ALUZ.LTG | 714.535.7900
WET LOCATION APPLICATIONS
1
Measure area where luminaire will be installed. Use a laser line to
create a reference line along installation area, ensuring consistent
alignment of mounting clips. Mark location where each mounting
clip will be installed along reference line.
2
Use 1 mounting clip every 2', rounded up. Use a minimum of 2
mounting clips per fi xture segment. For vertical applications, create
a stopper at the bottom of the run to prevent sliding.
3
Space mounting clips evenly throughout the run.
Example: 20' Run.
8'
3" Gap
Mounting Clip
ASSEMBLED DIMENSIONS
2.55"
3.98"
2.97"
MC
MC with Louver
2.55"
4.99"
3.98"
MC-3
MC-3 with Louver
Mounting Clips
20'
8'
4'
Junction between luminaire segments
2.60"
3.98"
MC with Reflector
2.60"
4.99"
MC-3 with Reflector
Installation Instructions
9 / 11 / 2023 / Rev 4
Page 4 of 13
2.60"
2.60"