Operating Instructions and Parts Manual
Installation
(continued)
Grounded
Check
Outlet
Valve
Inlet Pipe
14 in.
Figure 1
Dia.Min.
Flood risk. If
fl exible discharge
hose is used, make sure pump is secured
in sump pit to prevent movement.
Failure to secure pump could allow pump
movement and switch interference and
prevent pump from starting or stopping.
3. A check valve is required in the
discharge line to prevent back-flow
when the pump shuts off. It is best
to install the check-valve directly to
the pump discharge. Thread a check
valve into the pump discharge.
4. Connect 1-1/4 in. or 1-1/2 in. rigid
pipe to rubber boot on check valve.
(Reverse boot for 1-1/2 in. diameter
pipe.) Tighten hose clamps.
Support pump and
piping when
assembling and after installation.
Failure to do so could cause piping to
break, pump to fail, etc. which could
result in property damage and/or
personal injury.
Make sure there is
adequate room for
the fl oat switch to move freely during
operation (see Figure 2).
Place pump
where the
fl oat will
not be
obstructed
A freely
moving fl oat
ensures that
the pump will
perform properly.
NOTICE: An obstructed fl oat will
cause the pump to fail.
Figure 2: Freely moving fl oat switch
www.blueangelpumps.com
5. Protect electrical cord from sharp
objects, hot surfaces, oil and
chemicals. Avoid kinking the cord and
replace damaged cords immediately.
6. A sump pit cover must be installed
to prevent debris from clogging or
damaging the pump.
Operation
24 in.
Min.
disconnect the power source
before attempting to install,
service, relocate or maintain
the pump. Never touch sump pump,
Inlet
pump motor, water or discharge piping
Screen
when pump is connected to electrical
power. Never handle a pump or pump
motor with wet hands or when standing
on wet or damp surface or in water.
Fatal electrical shock could occur.
1. A ground fault circuit interrupter
(GFCI) is required.
is supplied with a grounding conductor
and grounding type attachment plug.
Use a grounded receptacle to reduce the
risk of fatal electrical shock.
Never cut off the round grounding
prong. Cutting the cord or plug will
void the warranty and make the pump
inoperable.
2. This pump is only for use on 120 Volt
(single-phase), 60 hz, 15 amp service
and is equipped with a 3-conductor
cord and 3-prong, grounding type plug.
DO NOT USE AN EXTENSION CORD.
3. Insert the pump power cord plug
directly into a GFCI protected 120
Volt outlet (See Fig. 3).
Power
Figure 3
4. Fill sump with water. The pump
will start automatically when the
water has filled the sump to a depth
of approximately 9 in. The pump
will stop when the water depth is
approximately 4 in. The pump will
recycle thereafter as required.
Always
Risk of electrical
shock! This pump
Grounded
Grounding
Outlet
Blade
TEST
RESET
Cord
2
BCS, BSPF, and SSBCS Series
Do not operate the
pump unless it
is submerged in water. Dry running
causes pump failure.
5. While the pump is draining the pit,
verify that the discharge piping is
carrying the water to a point several
feet away from the foundation.
6. If pump discharge line is exposed
to freezing temperature, the
exposed line must be pitched to
drain. Trapped water will freeze and
damage the pump.
NOTE: The motor is equipped with an
automatic reset thermal protector.
Maintenance
Always
disconnect the electrical
supply before attempting to
install, service, relocate or
perform any maintenance. If the power
source is out of sight, lock and tag
in the open (off) position to prevent
unexpected power application. Failure
to do so could result in fatal electrical
shock. Only qualifi ed electricians should
repair this unit. Improper repair could
result in fatal electrical shock.
1. Let the pump cool for a minimum of
two hours before servicing because
the pump contains hot oil under
pressure and the motor is hot.
2. Disassembly of the motor prior to
expiration of warranty will void the
warranty. If repairs are required, see
troubleshooting chart.
3. Inlet should be kept clean and free
of all foreign objects and inspected
annually. A clogged inlet will
damage pump.
4. Pump should be checked monthly
for proper operation. Check pump
by following step 4 listed in the
operation section.
This pump contains
dielectric oil for
cooling. This oil can be harmful to
the environment. Check the state
environmental laws before disposing
this oil.