CLOROX CLX1000 Manual do operador - Página 5

Procurar online ou descarregar pdf Manual do operador para Pulverizador de tinta CLOROX CLX1000. CLOROX CLX1000 12 páginas. Electrostatic sprayer

CLOROX CLX1000 Manual do operador

Protective Gear

Personal Protective Equipment (PPE) must comply with the American
National Standards Institute, ANSI Z87.1-1989 standard if purchased
after July 5, 1994, or ANSI Z87.1-1968.
• Eye and face PPE shall be distinctly marked to facilitate identification
of the manufacturer. [1910.133(a)(4)].
• The following minimum requirements must be met by all protective
devices. Protectors shall:
- Provide adequate protection against the particular hazards for
which they are designed.
- Be of safe design and construction for the work to be performed.
- Be reasonably comfortable when worn under the designated
conditions.
- Fit snugly and not unduly interfere with the movements
of the wearer.
- Be durable.
- Be capable of being disinfected.
- Be easily cleanable.
- Be distinctly marked to facilitate identification only
of the manufacturer.
RECOMMEND USE OF FULLY ENCLOSED EYEWEAR
PROTECTIONS, SUCH AS GOGGLES, WHEN USING THIS DEVICE.
ALWAYS USE APPROPRIATE PPE, LISTED ON THE CLOROX-
APPROVED PRODUCT'S SAFETY DATA SHEET (SDS).
CLOROX SDS'S CAN BE FOUND AT
WWW.CLOROXPROFESSIONAL.COM/SDS

IMPORTANT SAFETY PRECAUTIONS

When using an electrical appliance, it is important to understand that
some circuits are electrically live, even when the power switch is in
the off position. Basic safety precautions should always be followed to
reduce the risk of burns, fire, electrical shock, injury and/or death.

Power Connection

Our power plug must be used with a 3-prong grounded outlet, rated
for no less than 15A service. Always verify before product use. This
appliance is for use on a nominal 120V/60Hz circuit with a verified
ground plug. Check with a qualified electrician to insure you have the
correct electrical service and grounding.

Grounding Instructions

This appliance must be grounded. In the event of malfunction or
breakdown, grounding provides a path of least resistance for electric
current to reduce the risk of electric shock. This appliance is equipped
with a cord having an equipment-grounding conductor and a grounding
plug. The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local codes and
ordinances. Never use an adapter with this product.
DANGER: Improper connection of the equipment-grounding conductor
can result in a risk of electric shock. The conductor with insulation
having an outer surface that is green, with or without yellow stripes,
is the equipment-grounding conductor. If repair or replacement of
the cord or plug is necessary, do not connect the equipment-ground
conductor to a live terminal. Check with a qualified electrician
or serviceman if the grounding instructions are not completely
understood or if in doubt as to whether the appliance is properly
grounded. Do not modify the plug provided with the appliance — if
it will not fit the outlet, have a proper outlet installed by a qualified
electrician. Never use an adapter with this product.

Extension Cord

Clorox provides a 25-foot extension cord with each Total 360™
Electrostatic Sprayer and strongly recommends that you use
this approved extension cord. Make sure your extension cord is in
good condition. Inspect cords periodically and replace if damaged.
If an alternate extension cord is used, be aware that an undersized
extension cord will cause a drop in-line voltage, which could result
in loss of power, damage to the product and/or overheating.
Always use a sufficiently rated extension cord.
IMPORTANT: Clorox recommends using a 12/3 gauge extension
cord, no longer than 100 feet (30.5m). Additionally, Clorox also
recommends the use of a GFCI (ground fault circuit interrupter) power
outlet or extension cord. When equipped on the extension cord, always
position the GFCI toward the power outlet.
| 5