Asko DW95 Manual - Página 5
Procurar online ou descarregar pdf Manual para Máquina de lavar loiça Asko DW95. Asko DW95 19 páginas.
ELECTRICAL FUNCTION
CONTROL UNIT
DW951, 952, 95C has an electro-mechanical timer.
CIRCULATION PUMP
The circulation pump consists of an asynchronous motor and pump,
constructed in an integrated unit. A 4 µF capacitor is fitted to ensure
reliable starting of the circulation pump.
OUTLET PUMP
The outlet pump consists of a synchronous motor and pump, constructed
in an integrated unit.
INLET VALVE
Depending on model, there are three types of inlet valves:
1. With safety valve: Two solenoids independant from each other or valve
seats are connected to a unit.
2. Single-unit type: A solenoid and valve seat.
3. Softener valve: Two valves in shunt, one for the regeneration of the softe
ner and the other for normal inlet.
HEATING ELEMENT
Heating elements with the following capacities: 1800 W alt. , 2500 W
THERMOSTAT
Different thermostats are mounted, depending on model:
30/70°C
64153°
60°C
HIGH TEMPERATURE CUTOUT
Thermostat with switch-off-function at 88°C, 190°F prevents the heating
element from remaining continously energised if the control unit or the timer
should fail.
DW 950 / 951 / 952 / 95C
Thermostat with two switch-off functions with the temperatures
30°C (reset at 22°C) and 70°C (reset at 62°C) for temperature
stop in pre-wash or drying, respectively.
Thermostat with two switch-off functions with the temperatures
64° C (reset at 56° C) and 53° C (reset at 45° C) for temperature
stop in main wash and last rinse at high, or low temperature,
alternately.
Thermostat with oneswitch-off functions with the temperatures
60°C (reset at 52°C) for temperature stop in main-wash and last
rinse on models without temperature selction.