Aktakom AM-1171 Руководство пользователя - Страница 9
Просмотреть онлайн или скачать pdf Руководство пользователя для Мультиметр Aktakom AM-1171. Aktakom AM-1171 11 страниц. Digital multimeter
Range
Display value
Diode
forward
voltage drop
If Buzzer emits a
long sound and the
resistance of the
two
points
measured as 30Ω
Overload protection: 250V DC or AC peak value.
XIV. Capacity (C)
1. Press "
" button and respectively plug in the red and black meter pens into "
2. Circularly press "
symbol will appear on the LCD screen. No manual measurement range and analog bar will be displayed in Capacity mode.
Caution:
a) When measuring the capacity, all the powers within the tested circuits must be disconnected and the capacitance shall be
sufficiently discharged
b)When measuring big capacitors, it takes a longer time, about 100uF per 15 seconds.
c) When the measurement is completed, immediately disconnect the meter and the measured circuit.
Range
40nF
400nF
4μF
40μF
200μF
Overload protection: 250V DC or AC peak value.
XV. Frequency (Hz)
1. Press "
" button to conduct frequency measurement.
Respectively plug in the meter pen into "VΩHz"and"COM".
2. Have the testing end of the meter pen connected in parallel with the signal sources to be measured and read the results
from the display. (Note: No analog bar will displayed in this mode)
3. When testing frequency, press "Hz/DUTY" once to conduct duty cycle measurement. Press "Hz/DUTY" once more to
enter the frequency status.
4. Read the current results from the display.
Caution:
a) Do not input signals higher than 60V, otherwise it may
damage the instrument and pose dangers to human safety.
b) After all the measurements are completed, it is necessary
to disconnect the meter pen and the tested circuit.
www.tmatlantic.com
Measurement
condition
Forward DC current
is about 1.0mA, and
backward voltage is
about 3.0V.
Open circuit voltage
is about 1.2V
is
" button and select the automatic measurement range of capacity. Meanwhile, the corresponding
Accuracy
Resolution
±(5.0%+30d)
10pF
100pF
±(3.5%+8d)
1nF
10nF
±(5.0%+10d)
100nF
diode
switch
capacitance
switch
- 8 -
buzzer
switch
"and"COM".