Barnes 3SE-DS Series Руководство по установке и эксплуатации - Страница 11
Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Промышленное оборудование Barnes 3SE-DS Series. Barnes 3SE-DS Series 17 страниц. Submersible sewage ejector
Также для Barnes 3SE-DS Series: Руководство по установке и эксплуатации (20 страниц), Руководство по установке и эксплуатации (18 страниц)
![Barnes 3SE-DS Series Руководство по установке и эксплуатации](/uploads/products/server2/1103812/1103812.jpg)
Stationary Member (31A)
Polished Face Out
Seal Plate (1)
FIGURE 6
Place spring (31c) over shaft and in place on rotating member
(31b), making sure it is seated on retainer and not cocked or
resting on bellows tail. Slide retaining ring (31d) over shaft and
let rest on spring (31c). Replace retaining ring (49) onto shaft.
Set one square ring (8) in groove on seal plate (52) and lower
spacer (50) onto seal plate (52). Seat one square ring (8) onto
groove on spacer (50) and lower seal plate (1) onto spacer
(50). Insert two socket head cap screws (51) and torque to 60
inch pounds. Repeat insertion of seal for outer seal. Assemble
impeller and volute as outlined in paragraph F-2.2. Replace oil
as outlined in paragraph F-1.3.
Motor & Bearing Bracket
Stationary
Bullet
FIGURE 7
Seal Pusher
Rotating Member (31D)
Seal Pusher
SECTION: G REPLACEMENT PARTS
G-1 ORDERING REPLACEMENT PARTS:
When ordering replacement parts, ALWAYS furnish the
following information:
1. Pump serial number and date code. (Paragraph G-4)
2. Pump model number. (Paragraph G-3)
3. Pump part number. (Paragraph G-2)
4. Part description.
5. Item part number.
6. Quantity required.
7. Shipping instructions.
8. Billing Instructions.
G-2 PART NUMBER:
The part number consists of a six (6) digit number, which
appears in the catalog. A one or two letter suffix may follow this
number to designate the design configuration. This number is
used for ordering and obtaining information.
G-3 MODEL NUMBER:
This designation consists of numbers and letters which
represent the discharge size, series, horsepower, motor phase
and voltage, speed and pump design. This number is used for
ordering and obtaining information.
G-4 SERIAL NUMBER:
The serial number block will consist of a six digit number,
which is specific to each pump and may be preceded by
a alpha character, which indicates the plant location. This
number will also be suffixed with a four digit number, which
indicates the date the unit was built (Date Code). EXAMPLE:
A012345 0490.
Reference the six digit portion (Serial Number) of this number
when referring to the product.
11