Motor - Slide lower bearing (6) and motor (20) squarely into the
seal plate (1) until bearing seats on the bottom. Torque motor
bolts to 17 inch pounds. Make wire connections per paragraph
F-3.3. Set square ring (8) in groove on seal plate (1), lower
motor housing (5) down onto seal plate (1) while aligning
holes. Place socket head cap screws (9) through seal plate (1)
into motor housing (5) and torque to 60 inch pounds.
F-3.3) Wiring Connections:
Check power cable (30) and control cable (32) for cracks
or damage and replace if required (see Fig. 4). Place parts
(30a,b&c) and hex nut (16) on power cord (30), and parts
(32a,b &c) on control cable (32). Bring cord sets (30) and (32)
through opening in top of motor housing (5), and reconnect
motor leads to power cable (30) and sensor leads to control
cable (32) using connectors (23), and in addition use (40) and
(41) for 3 phase, as show in Fig. 3.
SINGLE PHASE, 115/230 VOLT AC
Power Cable (30) Motor Lead Number
Green (Ground)
Black
White
Flag Terminal
Flag Terminal
THREE PHASE, 200/230 VOLT AC
Power Cable (30) Motor Lead Number
Green (Ground)
Black
Red
White
Green
1
2
Capacitor
Capacitor
CONNECTORS
CONNECTORS
Green
1 & 7
2 & 8
3 & 9
FIGURE 3
4, 5 & 6 Together
THREE PHASE, 460 VOLT AC
Power Cable (30) Motor Lead Number
Green (Ground)
Black
Red
White
TEMPERATURE SENSOR ONLY
Control Cable (32)
Black
White
MOISTURE & TEMPERATURE SENSORS
Control Cable (32)
Black
White
Red
Orange
Green
9
CONNECTORS
CONNECTORS
Green
1
2
3
4 & 7 Together
5 & 8 Together
6 & 9 Together
Lead Number
P1 (Thermo Sensor)
P2 (Thermo Sensor)
Lead Number
P1 (Thermo Sensor)
P2 (Thermo Sensor)
W1 (Moisture Sensor)
W2 (Moisture Sensor)
Ground