4
mounting Unit To bracket
3.1.1 Preferred Option - Solid Wall
The MVHR unit fixed to a solid wall construction using the
mounting bracket provided.
5
Ducting in the
ceiling void.
Side view of unit
mounted on the
block wall in a
cupboard.
MVHR-DRAIN
Condensate drain,
uninsulated drain
o
pipe with min 5
fall running to SVP.
Solid Wall mounted Unit Installation
3.1.2 Alternative Option - Non-Solid Wall
If it is not practical to use a solid wall, the MVHR unit should be
fixed to a stud partition with a 25mm minimum thickness MDF
panel solidly fixed behind the plasterboard.
If fixing to a stud wall the mDF panel should extend, width wise, over a
minimum of 3 vertical studs with centres of no more than 400mm. Add
additional vertical supports if necessary.
Height wise, ideally, the mDF panel should extend from floor to ceiling
but as a minimum should be a least 2m high.
Fix the mounting bracket to the wall (Figure 3) and use the wall
mounted bracket to mount the unit on (Figure 4).
671950 | DeCembeR 2020
Valve in ceiling.
3.2 Loft Mounting
3.2.1 Option A - Tank Stand
The mVHR unit should be positioned on a tank stand using the Anti-
vibration tray assembly discarding the angle brackets.
Anti-vibration tray assembly (HRXe-HeRA-AV) is to be purchased
separately.
3.2.2 Option b - Angled brackets
The mVHR unit should be positioned on a 25mm minimum thickness
mDF panel that is vertically fixed across the roof trusses to form a solid
false wall.
Add additional vertical supports if necessary. Use the Anti-vibration
tray assembly (HRXe-HeRA-AV) including the angle brackets, to be
purchased separately.
6
Ducting in the
ceiling void.
Side view of unit
mounted in a
cupboard fixed to
a stud partition
with the 25mm
MDF fixed behind
the plasterboard.
MVHR-DRAIN
Condensate drain,
uninsulated drain
o
pipe with min 5
fall running to SVP.
Solid Wall mounted Unit Installation
7
Tank Stand Loft mounted Unit Installation
Rear panel of
=
MVHR unit
4 x AV
Mounts
Valve in ceiling.
619
559 CRS
=
PAGe 3