AUTO IONS REDUCE
YES/NO
This feature automatically adjusts the
IONS OUTPUT to a lower value after 30
days, if NO is selected you will return to
5)SYSTEM SETUP, if YES is selected
then you are prompted for the fall back
current;
IONS FALLBACK
SET FOR xxx mA
6) SAVE & EXIT
When this menu is selected, push Enter to
save ALL settings, the unit will return to
normal operation automatically. If any of
the menu items are left unattended for 3
minutes the menu will time out and
automatically save all settings and return
to automatic operation.
THE ENTER/MANUAL BUTTON
If at any time the ENTER/MANUAL button
is pressed the pump is switched on and
the following will be displayed;
ON/OFF ↑ ↓
ENTER = AUTO
This function is used for system back
wash, pool vacuuming, spa heating, etc.
The filter pump is allowed to run but the
Ions Output is turned to OFF. Use the
Up/Down buttons to turn the pump
ON/OFF, after four hours the system will
automatically return to normal automatic
run mode.
PWP2_Instructions_rA1.docx
SPECIAL TEST MENU
This menu is for special access and
should normally not be required.
To enter test mode, press and hold the
Enter button while the power to the unit is
turned on, after 2 seconds release the
Enter button.
OUTPUT CURRENT:
NORMAL (DEFAULT)/HIGH
When output current is set to high it
enables higher values to be set under the
'3) IONS OUTPUT' menu, when set to
normal the maximum value is 250mA but
when set to high it can be set as high as
400mA.
If you select NORMAL (DEFAULT) it will
also enter the production test and will
perform a short output current test then
resetting itself and returning to normal
operation.
Normal Operation for factory default
settings: Between 09:00 and 13:00 or
16:00 and 20:00 the PUMP will be on, as
well as IONS ACTIVE & PUMP ON LEDs,
ionising current is set for 200mA. When
minutes of the day is between; 0-14 then
TOP POLARITY LED is ON, 15-29 then
BOTTOM POLARITY LED is ON, 30-44 then
TOP POLARITY LED is ON, 45-59 then
BOTTOM POLARITY LED is ON. At other
times ALL LED's should be OFF.
6