Door Controls DC One Руководство по установке - Страница 15

Просмотреть онлайн или скачать pdf Руководство по установке для Система открывания дверей Door Controls DC One. Door Controls DC One 20 страниц. Automatic sliding door retrofit drive assembly

17. TROUBLE SHOOTING TIPS

Before wiring any sensors into the DC One control, it is a good idea to apply power and test the door to ensure it will power
open and closed when the TEST button is pressed.
Use caution during this test as the sensors will not be operational
The following inputs have status LEDs to help identify problems:
Power
Control On
Door Locked
Heartbeat
One Way
Partial Open
Hold Open
Reset
The heartbeat LED should be blinking. If not, cycle power on the control. If the heartbeat LED is still not blinking,
the control is malfunctioning and should be replaced.
If programming of the control is unsuccessful, it is easiest to restore the default values and then start over, rather
than trying to correct any faulty programming.
When power is applied, the door powers open and stays open.
Motion or presence sensor output is being held (closed circuit). If unsure which sensor, unplug one
by one until fault is isolated. Correct as necessary.
Safety beam is blocked or is faulty. Correct as necessary.
Door handing is set incorrectly. Enter program mode and change hands.
Door powers closed and then stay closed.
Press the TEST button on the face of the DC One control. Door should power open and then
close. If it does not open, door handing is set incorrectly. Enter program mode and change hands.
Door will not open or close.
As a first step, always check the DC One digital display for error messages and proceed
accordingly.
Breakout switch is not wired properly. If red light is on for breakout function on I/O interface, it
means that the control is in a breakout condition. Check to ensure breakout polarity is set
correctly.
On/Off switch is not wired properly or it is in the off position. If the switch is in the on position, the
green LED to the left of the display will be on.
Important
Upon completion of your retrofit, ensure all functions of the door perform satisfactorily. Walk-test the door
according to AAADM recommended guidelines and correct all discrepancies, if any, before leaving the job site.
DO NOT compromise proper performance. If repairs cannot be immediately made, shut the door OFF and inform
the owner of any special instructions and corrective actions.
Contact Door Controls USA for further technical support when needed:
Door Controls USA, Inc.
321 VZ County Road 4500
Ben Wheeler, TX 75754
Phone: 1-800-437-3667
Fax: 1-800-356-8858
DoorControlsUSA.com
DC One V3 Installation Manual
M-0015 REV 06222017 P10
Safety
Inner Sensor
Outer Sensor
Emergency Open
Ratchet
Activation
Breakout
Night Mode
Page 13 of 15