SETTING THE OPEN & CLOSE LIMITS ....Menu 1
1) Ensure the ba ery is connected to the operator.
2) Press the SET bu on to enter the Programming Menu (Pr).
3) Press the DOWN bu on un l Li is visible.
4) Press the SET bu on. The display will change to oL.
5) Use the UP and Down bu ons to move the door to the OPEN posi on. The Trolley
must stop 2mm away from the Sprocket Assembly. If the Trolley does not reach the
Sprocket Assembly, then a Channel End Stopper (not supplied) must be fi ed
6) When the door is in the open posi on, press the SET bu on. The display will change
to cL.
7) Use the UP and Down bu ons to move the door to the CLOSE posi on.
8) When the door is in the closed posi on, press the SET bu on. The display will change
to CL. Adjust the Lower Limit Adjus ng Bolt to be 2mm above the floor.
9) The open and closed limits are now set.
SETTING THE OPENING & CLOSING FORCE ....Menu 2
1) Ensure the ba ery is connected to the operator.
2) Press the SET bu on to enter the Programming Menu (Pr).
3) Press the DOWN bu on un l the Force Limit Menu (Fo) is visible.
4) Press the SET bu on to enter the Force Limit Menu. The display will change to the
current Force Limit value F3 (this is the default se ng).
5) Press the UP and DOWN bu ons to scroll through the Force Limit values. F0
(minimum force) to F9 (maximum force). ***
6) Press the SET bu on on the chosen Force Limit value to accept.
***
Cau on: too high a force se ng could cause injury or damage!!
ENABLE OR DISABLE SAFETY BEAMS ....Menu 3
1) Ensure the ba ery is connected to the operator.
2) Press the SET bu on to enter the Programming Menu (Pr).
3) Press the DOWN bu on un l the Beams Menu (bE) is visible.
4) Press the SET bu on to enter the Beams Menu. The display will change to (by)
5) Press the UP and DOWN bu ons to toggle between ENABLE (by) and DISABLE (bn).
6) Press the SET bu on on either ENABLE (by) or DISABLE (bn) to select.
SET
SET
I
SET
SET
SET
SET
SET
SET
SET
SET
14
SECURING THE DRIVE CHANNEL FOOT TO THE FLOOR
1) With the door/s s ll closed, and ensuring
that the Manual Release Mechanism has
been released, li the door/s by hand,
P r
holding the Cross Tube. The door/s need
only be li ed about 50cm and then lowered
again to the closed posi on. This procedure
l i
will automa cally place the Drive Channel
Foot the correct distance from the wall.
2) Without moving the Drive Channel toward
o L
or away from the door, use a Spirit Level to
confirm that the channel is s ll ver cal.
3) Make marks on the floor through the two
holes in the Drive Channel Foot.
4) Move the Drive Channel slightly, enough to
allow for holes to be drilled in the floor and
c L
the 10mm wall plugs to be inserted.
(The Door Li ing Tube/s can be removed to
make this easier).
5) Move the Drive Channel back into posi on
and fasten the Drive Channel Foot to the
floor using the two coach screws
C L
Before applying power to the operator, manually li the door/s to ensure that there is free movement of the
Li ing Assembly on the Drive Channel.
Li the door/s manually to various heights and ensure that the door/s do not close under their own weight. If
they do then it will be necessary to get an experienced door fi ng contractor to tension the door springs.
Place the 12 volt ba ery on top of the Drive Channel at the back of the operator and secure it in place with the
Velcro straps that are in place.
p r
1
Velcro straps
F o
2
12v Ba ery
3
Door U-Brackets
F 3
4
Drive Channel
BEFORE PROGRAMMING & COMMISSIONING THE OPERATOR
The LUX DC12 operator uses the 12V ba ery for normal opera on, it is important that the ba ery is always
Se ng the Open and Close limits:
A er the operator has been assembled, fastened to the wall and a ached to the door (s), it must be
p r
programmed to recognise the door's Open and Close limits.
On first power up, or a er a factory reset, the operator's LED display will flash
door limits need to be set. The operator will not allow opera on of the door un l this process has been
b E
completed.
Note: Depending on the motor wiring polarity, the UP and DOWN bu ons on the operator may not
b y
necessarily correspond with the actual direc on that the door is moving in. The operator will automa cally
correct this once the Open and Close Limits have been set.
Follow 'Se ng the Open and Closed Limits...Menu 1' to program the limits for the door(s).
Once the limits have been set, the door can be opened and closed using the UP or DOWN bu ons on the
operator.
If, a er the ini al setup, the limits need adjus ng the Programming Menu (Pr) can be entered again by pressing
the SET bu on and the limits can be reset.
:
Please Note
POSITIONING & SECURING THE BATTERY
1
4
connected when the operator is in use.
nL
. This is the indica on that the
Refer to 'Se ng the Physical End Stops' on page 13.
11
2
3