To prevent the risk of fire, allow the ashes to cool outdoors inside a metal container or in the
stove and eliminate them in compliance with current local regulations.
4.2 Cladding maintenance
Clean the cladding only when the stove is cold
COLA ceramics are handicraft production and therefore may have minor surface imperfections such as
tiny spots or slight colour differences.
It is advisable to use a soft dry cloth to clean the ceramic surfaces; the use of detergents could
highlight any imperfections
4.3 Cleaning the glass
The glass can be cleaned using a damp cloth and specific non-abrasive detergents.
Do not clean the glass when the stove is operating. The glass must only be cleaned when the
stove is cold.
4.4 Cleaning the flue
A reduction in heat output is nearly always due to obstruction of the flue. Also, the presence of burnt
gases with odours can be a sign of an obstructed flue.
The flues of your stove must be cleaned at regular intervals. The amount of soot and the frequency of
cleaning will depend largely on the type of fuel and the type of use (low or high heat output).
To avoid unnecessary dust, carry out cleaning according to the following instructions:
clean only when the stove is off;
-
-
close all openings which are not to be cleaned;
-
remove the flue pipe and clean outdoors;
remove the deposits inside the stove with a wire brush;
-
all the residuals removed from the grate or the ash pan must be taken away;
-
in any case, detach the pipe from the flue.
-
When fitting the pipes, make sure not to damage the enamelled or painted parts and the seals.
Dispose of cleaning waste in accordance with the current local regulations.
5 – TROUBLESHOOTING
5.1 The stove does not work
-
Make sure the connection and size of the flue are suitable for the stove's heating power.
-
Make sure the flue is constructed in conformity with the current regulations.
-
Make sure the flue inspection doors and openings are closed and sealed.
-
Make sure no other appliances are connected to the flue.
5.2 Difficult lighting
Open the primary air control and the damper.
-
-
Use wood and lignite blocks with low moisture content.
-
Make sure the room is well-ventilated, to ensure a sufficient amount of oxygen
in the air.
-
Make sure the flue is suitable for the stove's heating power.
5.3 Smoke leaks
-
Check the flue draught.
-
Make sure the flue pipe connection complies with the seal requirements.
-
Make sure the ash does not obstruct the primary air grille.
-
Make sure combustion residuals do not block the flue pipe.
-
Make sure the primary air control is open.
5.4 The glass gets dirty quickly
-
Make sure the fuel is of a recommend type.
-
Make sure the wood is seasoned and dry.