Electronic expansion valve control unit
PreCaution for Use
1. This product may cause an electric shock in handling. Please do not attempt to open it with power
turned on.
2. This product should be installed in a place fixed secured by a rack or panel.
3. This product can be used under the following environmental condition
① Indoor ②Pollution Degree 2 ③At an altitude of 2000m or below ④Installation CategoryⅡ
4. To turn on or turn off power supply for this product, please the circuit breaker or switch of a standard
product of IEC 60947-1 or IEC 60947-3 product and install it within a close distance allowing
convenient operation by user.
5. Please be understood that if this product is dismantled or modified discretionary, after sales service
will not be able to be provided.
6. An output wire to be used for this product should be inflammable grade FV1 (V-1 grade or above),
the thickness of the wire should be AWG No. 20 or above. (0.50㎟)
7. In order to prevent it from an inductive noise, please maintain the high-voltage wire and power wire
separated.
8. Please avoid installing the product in a place where a strong magnetism, noise, severe vibration
and impact exist.
9. When extending the sensor wire, use a shield wire and do not extend it unnecessary long.
10. The sensor wire and signal wire should be away from the power and load wires using conduits
separately installed.
11. Please avoid using the product near a device generating strong high frequency noise (high-frequency
welding machine, high-frequency sewing machine, high-frequency radiotelegraph, high capacity SCR
controller)
12. PRODUCT'S DAMAGES OTHER THAN THOSE DECRIBED IN THE GUARANTEE CONDITIONS PROVIDED
BY THE MANUFACTURER SHALL NOT BE RESPOINSIBLE BY US.
Please use this product after attaching double or more safety device without fail if you use this product for
control of equipment which have a big effect on human life or on property (e.g.:nuclear control, medical
instrument, vehicle, railroad, aviation, combustion apparatus, amusement equipment, safety device, etc.)
Basic Specification
FX32EV
Model
Power
AC100 - 240V ~ , 50/60Hz (MAX 4VA)
Control Mode
Electronic expansion valve control unit using PID control algorithm
Connection
screw bolt terminal block (1.5mm wire available)
Terminal
SSR output 1 point (expansion valve on/off), Relay output 1 point (alarm port)
Input/
Pt1000Ω temp. sensor 1 point, 4~20mA
Output
pressure sensor input 1 point (built-in sensor loop power)
Operation
Temp. -10~50℃ (when no dew condensation)
Storage
Temp. -20~60℃, Humidity Under 90%RH
Sensor
Temp. sensor (DPR-PT1K-P6D50L,-100~100'C)
Pressure sensor (-1~9bar or 0~30bar)
Display
Indication is possible in 0.1℃ unit between -19.9 and 99.9.
outside of that range, in 1℃
Order Information
FX32EV - 00 :
Basic model
RS-485 communication function model (MODBUS RTU MODE)
FX32EV - R4 :
(※ communication cable is included)
RS-232 communication function model (MODBUS RTU MODE)
FX32EV - R2 :
(※ communication cable is included)
Pressure transmission output function model or
FX32EV - A1 :
For 4~20mA type electronic expansion valve
Accessory
Suction Pressure Sensor : DP506
Pressure measure range : -1~9bar, 0~30bar, 0~16bar
Operating temperature : -40 ~ 125℃
Accuracy : ±0.5% FS
Protection level : IP67
Signal output : 4~20mA (2 Wire)
Temperature Sensor : DPR-PT1K-P6D50L*3m
Sensor type : Pt1000Ω
Measurement range : -100 ~ 100℃
Accuracy : ±0.3℃
Probe : Dia.6, 50mm,SUS304
Protection level : IP67
Cable : 2C X 0.5mm, Stainless mesh shield teflon cable
FX32EV
2
DOTECH,INC l http://www.dotech21.com
Dimensions and Panel Cut-Out Form
8
70
28
Connection Diagram
FX32EV
Alarm
EVout
1 2
3
4
5
AC100 - 240 V ~
50/60Hz
EV
Option
RS-485 COMM.
RS-232 COMM.
OPTION MODULE
OPTION MODULE
1
1
2
2
TRX
3
3
TRX
4
4
SG
Constitution
FX32EV
Ev
SH
T
P
Indicator Lamp
Ev
Lighting when expansion valve is on
SH
The degree of superheat
T
Temperature
P
Pressure
bar
℃ : Temperature, bar : Pressure
Lighting when trip, flickering when alarm
Operation Button
Program setup
Push twice successively and
rst
quickly when clearing alarm
of manual return type
Execution of options or
input of setup value
Initialization of Setup Values
rst
If pushing for 10 sec. at the same time, setup values are initialized
6F, JOONGANG-ILBO 778 Wonsi-Dong, Danwon-Gu, Ansan-Si,
Gyeonggi-Do, Korea TEL : +82-31-495-3767 / FAX : +82-31-495-3917
REV. 2010. 5. 3
(unit : mm)
78
FX32EV
Ev
reset
mv
SH
T
P
※ Panel Cut-Out Form : 71 X 29 mm
ID1 Pt1k COM 4~20mA +V
6
7
8
9 10 11
start
temp
pressure
4~20mA Output
OPTION MODULE
1
2
RXD
4~20mA
3
TXD
4~20mA
4
GND
SG
reset
mv
bar
Move between menus &
Increase of setup value
mv
Confirmation of valve control
output (during pushing button)
Menu movement or
decrease of setup value
35
1