Baumer GNAMG Series Руководство - Страница 33

Просмотреть онлайн или скачать pdf Руководство для Аксессуары Baumer GNAMG Series. Baumer GNAMG Series 41 страница. Inclination sensor with canopen interface

Baumer GNAMG Series Руководство
SDO Abort Message
If SDO communication does not run properly, the SDO response will come with an abort code:
05040001h
06010000h
06010001h
06010002h
06020000h
06090011h
06090030h
06090031h
08000000h
08000020h
08000021h

4.3. Useful information on the sensor

Setting a new Node-ID
1. Setting a new Node-ID is by using Baumer IVO-specific object 2100h.
2. After having set the new Node-ID latter must be stored in EEPROM by object 1010h.
3. Upon next init the sensor will log in with the new Node-ID.
Setting a new baud rate
1. Setting a new baud rate is by using Baumer IVO-specific object 2101h.
2. After having set the new baud rate latter must be stored in EEPROM by object 1010h.
3. Upon next init the sensor will log in utilizing the new baud rate.
4. ! DO NOT FORGET TO ALIGN THE NEW BAUD RATE WITH MASTER!
Shield
The inclination sensor's base plate should always be grounded. By principle the inclination sensor should be
connected by shielded cable.
Ideally, aim at a bilateral cable shield if possible. Take care that no compensating currents are drained off the
inclination sensor.
Manual_GNAMG_CANopen_EN.doc
21.11.12
: Command byte not supported
: Incorrect object access
: Read access on write only
: Write access on read only
: Object not supported
: Subindex not supported
: Value outside the limit
: Value too high
: General error
: Incorrect saving signature ("save")
: No data saving possible
33/41
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany