2:

Product assembly

Step 1:
Stripping wire
As shown in Figure 1, cut the wire. During cutting, ensure that the cut surface of the insulation layer is smooth, the
wire is not damaged, and the cut surface of the wire is flush.
Step 2:
Crimping contact
Use the automatic crimping tool or manual crimping tool to crimp the terminal. The width and height of the terminal
on the insulation layer cannot be greater than 2.6mm, as shown in Figure 2.
Step 3:
Check after crimping
Check appearance and pulling force after crimping terminals. The appearance must not be deformed. For details, see
lPC620. The pulling force should be measured according to the tension value corresponding to the actual wire
diameter, which should not be lower than the requirement of tension value in Table 1.
Figure 1
Figure 2
Table 1
Conductor
AWG
mm
2
22 AWG
0.324 mm
2
20 AWG
0.519 mm
2
18 AWG
0.823 mm
2
Crimping Width
Crimping Height
Pulling force
Pounds
N
8
35.6
13
57.9
20
89.0
11