DRAKE MQM6000L Руководство по эксплуатации - Страница 7
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Модулятор DRAKE MQM6000L. DRAKE MQM6000L 15 страниц. Multiplexing qam modulator
R1
RF OUTPUT
R
1, RF OUTPUT – This type "F" connector is the high
level (+40 dBmV), 54 to 1002 MHz, output from the
MQM6000L upconverter section.
R2, ASI INPUTS 1 through 6 - These six BNC type
connectors each accept multiprogram ASI format MPEG2
transport stream inputs.
R3, RS232 IN - Connection to a PC or modem for use with
remote control / monitoring program or for firmware
download.
Rear Panel Connections
R2
ASI INPUTS
1
2
3
4
5
R4, RS232 OUT - Loop to another MQM or DQT.
R5, AC Line Cord – For connection to the nominal
120 VAC power source. This unit is designed for use in
countries with 120 VAC power standards but the power
supply will accept an input voltage range of 90 VAC
minimum to 260 VAC maximum with a power line frequency
of either 50 or 60 Hz. The maximum power consumption is
15 watts.
R3
OUT
6
7
R4
R5
AC POWER
120 VAC 60 Hz
15 WATTS
IN
RS232